{
    "document_id": 13781,
    "page": 73,
    "width_pt": 720,
    "height_pt": 540,
    "rotation": 0,
    "pipeline_version": "paddleocr-vl-1.6+paul-48",
    "engine": "paddleocr_vl",
    "source_run_id": 13892,
    "item_count": 12,
    "counts_by_type": {
        "figure": 2,
        "list": 1,
        "list_item": 4,
        "text": 4,
        "title": 1
    },
    "build_ms": 1,
    "items": [
        {
            "id": "p73.1",
            "order": 1,
            "type": "title",
            "bbox": {
                "l": 29.28,
                "t": 521.28,
                "r": 397.92,
                "b": 420.24
            },
            "text": "NOISE Pollution\nOrdinance Language\nSierra Club",
            "attrs": {
                "block_label": "doc_title"
            },
            "level": 2
        },
        {
            "id": "p73.2",
            "order": 2,
            "type": "list",
            "bbox": {
                "l": 37.92,
                "t": 402,
                "r": 674.64,
                "b": 153.36
            },
            "text": "",
            "attrs": {
                "item_count": 4
            },
            "children": [
                {
                    "id": "p73.2.1",
                    "order": 3,
                    "type": "list_item",
                    "bbox": {
                        "l": 37.92,
                        "t": 402,
                        "r": 648,
                        "b": 337.92
                    },
                    "text": "Mitigation. Mitigation may include larger setbacks, indoor equipment placement, acoustic enclosures, critical-grade silencers, turbine inlet silencers, stack silencers, bypass-stack silencers, gas-compressor enclosures, barriers, berms, building orientation, reduced concurrency, startup/shutdown restrictions, testing-window restrictions, fan selection, transformer selection, speed controls, and operational limits.",
                    "marker": "H."
                },
                {
                    "id": "p73.2.2",
                    "order": 4,
                    "type": "list_item",
                    "bbox": {
                        "l": 41.52,
                        "t": 330,
                        "r": 658.56,
                        "b": 267.12
                    },
                    "text": "Post-construction verification. The operator shall fund post-construction sound verification after initial energization, after full operation, after Material Changes, and upon credible complaints. If sound limits are exceeded, the operator shall implement corrective action and may be required to curtail or suspend offending operations until compliance is demonstrated.",
                    "marker": "I."
                },
                {
                    "id": "p73.2.3",
                    "order": 5,
                    "type": "list_item",
                    "bbox": {
                        "l": 42.96,
                        "t": 258,
                        "r": 674.64,
                        "b": 209.52
                    },
                    "text": "Continuous monitoring. Continuous sound monitoring shall be required where any generator yard, primary generation facility, cooling yard, or major electrical infrastructure is within 1,000 feet of a Sensitive Receptor, or where required by the governing body based on the record.",
                    "marker": "J."
                },
                {
                    "id": "p73.2.4",
                    "order": 6,
                    "type": "list_item",
                    "bbox": {
                        "l": 44.16,
                        "t": 201.6,
                        "r": 669.12,
                        "b": 153.36
                    },
                    "text": "Vibration. The applicant shall evaluate vibration from generators, turbines, transformers, chillers, pumps, and construction. The municipality may impose vibration limits, setbacks, isolation, or monitoring necessary to protect neighboring properties and structures.",
                    "marker": "K."
                }
            ]
        },
        {
            "id": "p73.3",
            "order": 7,
            "type": "figure",
            "bbox": {
                "l": 354.7068,
                "t": 141.7729,
                "r": 686.25,
                "b": 1.6899
            },
            "text": "",
            "attrs": {
                "source": "pdf_image"
            }
        },
        {
            "id": "p73.4",
            "order": 8,
            "type": "figure",
            "bbox": {
                "l": 402.96,
                "t": 116.4,
                "r": 624.48,
                "b": 67.68
            },
            "text": "",
            "attrs": {
                "block_label": "image"
            },
            "children": [
                {
                    "id": "p73.4.1",
                    "order": 9,
                    "type": "text",
                    "bbox": {
                        "l": 458.64,
                        "t": 114.48,
                        "r": 623.52,
                        "b": 71.28
                    },
                    "text": "SIERRA CLUB\nSOUTHEASTERN PA GROUP"
                }
            ]
        },
        {
            "id": "p73.5",
            "order": 10,
            "type": "text",
            "bbox": {
                "l": 371.04,
                "t": 54.24,
                "r": 657.84,
                "b": 37.2
            },
            "text": "Model Large-Load Data Center Ordinance"
        },
        {
            "id": "p73.6",
            "order": 11,
            "type": "text",
            "bbox": {
                "l": 426,
                "t": 30.72,
                "r": 603.6,
                "b": 18.48
            },
            "text": "Public Education / Municipal Review Draft"
        },
        {
            "id": "p73.7",
            "order": 12,
            "type": "text",
            "bbox": {
                "l": 493.68,
                "t": 12.96,
                "r": 536.64,
                "b": 3.12
            },
            "text": "Version 7.2"
        }
    ],
    "excluded_furniture": {
        "first": [],
        "last": []
    }
}