{
    "document_id": 13781,
    "page": 71,
    "width_pt": 720,
    "height_pt": 540,
    "rotation": 0,
    "pipeline_version": "paddleocr-vl-1.6+paul-48",
    "engine": "paddleocr_vl",
    "source_run_id": 13892,
    "item_count": 8,
    "counts_by_type": {
        "figure": 2,
        "text": 5,
        "title": 1
    },
    "build_ms": 0,
    "items": [
        {
            "id": "p71.1",
            "order": 1,
            "type": "title",
            "bbox": {
                "l": 29.52,
                "t": 521.28,
                "r": 397.92,
                "b": 420.48
            },
            "text": "NOISE Pollution\nOrdinance Language\nSierra Club",
            "attrs": {
                "block_label": "doc_title"
            },
            "level": 2
        },
        {
            "id": "p71.2",
            "order": 2,
            "type": "text",
            "bbox": {
                "l": 17.04,
                "t": 400.08,
                "r": 683.76,
                "b": 269.28
            },
            "text": "1. Cumulative noise standard Noise compliance shall be evaluated at the receiving Sensitive Receptor and receiving property-line locations based on the combined modeled and measured contribution of the proposed LLDC and other existing, approved, pending, concurrently filed, or reasonably foreseeable data-center, generation, cooling, substation, transformer, BESS, fuel, and Associated Infrastructure sources within the Cumulative Impact Review Area. No approval shall be granted unless the applicant demonstrates that cumulative sound, tonal noise, low-frequency noise, infrasound where relevant, vibration, and testing/maintenance scenarios will comply with the applicable daytime, nighttime, tonal, low-frequency, and vibration standards."
        },
        {
            "id": "p71.3",
            "order": 3,
            "type": "figure",
            "bbox": {
                "l": 354.7068,
                "t": 198.9399,
                "r": 686.25,
                "b": 58.8568
            },
            "text": "",
            "attrs": {
                "source": "pdf_image"
            }
        },
        {
            "id": "p71.4",
            "order": 4,
            "type": "figure",
            "bbox": {
                "l": 402.96,
                "t": 173.52,
                "r": 624.48,
                "b": 125.28
            },
            "text": "",
            "attrs": {
                "block_label": "image"
            },
            "children": [
                {
                    "id": "p71.4.1",
                    "order": 5,
                    "type": "text",
                    "bbox": {
                        "l": 458.64,
                        "t": 170.88,
                        "r": 624.24,
                        "b": 129.36
                    },
                    "text": "SIERRA CLUB\nSOUTHEASTERN PA GROUP"
                }
            ]
        },
        {
            "id": "p71.5",
            "order": 6,
            "type": "text",
            "bbox": {
                "l": 370.8,
                "t": 111.12,
                "r": 658.08,
                "b": 94.32
            },
            "text": "Model Large-Load Data Center Ordinance"
        },
        {
            "id": "p71.6",
            "order": 7,
            "type": "text",
            "bbox": {
                "l": 426,
                "t": 87.6,
                "r": 603.6,
                "b": 75.84
            },
            "text": "Public Education / Municipal Review Draft"
        },
        {
            "id": "p71.7",
            "order": 8,
            "type": "text",
            "bbox": {
                "l": 493.44,
                "t": 70.08,
                "r": 536.88,
                "b": 59.76
            },
            "text": "Version 7.2"
        }
    ],
    "excluded_furniture": {
        "first": [],
        "last": []
    }
}