    "items": [
        {
            "id": "p133.1",
            "order": 1,
            "type": "figure",
            "bbox": {
                "l": 81.12,
                "t": 731.76,
                "r": 114.48,
                "b": 697.68
            },
            "text": "",
            "attrs": {
                "role": "page_header",
                "block_label": "header_image"
            }
        },
        {
            "id": "p133.2",
            "order": 2,
            "type": "header",
            "bbox": {
                "l": 120.48,
                "t": 721.68,
                "r": 247.92,
                "b": 703.92
            },
            "text": "Agilent Technologies",
            "attrs": {
                "block_label": "header"
            },
            "level": 2
        },
        {
            "id": "p133.3",
            "order": 3,
            "type": "header",
            "bbox": {
                "l": 328.32,
                "t": 757.92,
                "r": 427.44,
                "b": 717.84
            },
            "text": "Agilent Technologies, Inc.\n5301 Stevens Creek Blvd\nSanta Clara, CA 95051\nUnited States",
            "attrs": {
                "block_label": "header"
            },
            "level": 2
        },
        {
            "id": "p133.4",
            "order": 4,
            "type": "figure",
            "bbox": {
                "l": 75.24,
                "t": 735.72,
                "r": 254.64,
                "b": 690
            },
            "text": "",
            "attrs": {
                "source": "pdf_image"
            }
        },
        {
            "id": "p133.5",
            "order": 5,
            "type": "title",
            "bbox": {
                "l": 120.96,
                "t": 649.92,
                "r": 522.96,
                "b": 635.04
            },
            "text": "The Agilent Fragment Analyzer Systems - Unique Specifications and Facts",
            "attrs": {
                "block_label": "doc_title"
            },
            "level": 2
        },
        {
            "id": "p133.6",
            "order": 6,
            "type": "text",
            "bbox": {
                "l": 108,
                "t": 616.8,
                "r": 379.2,
                "b": 605.04
            },
            "text": "In the market, only the Agilent Fragment Analyzer systems provide:"
        },
        {
            "id": "p133.7",
            "order": 7,
            "type": "heading",
            "bbox": {
                "l": 124.56,
                "t": 593.04,
                "r": 274.08,
                "b": 582
            },
            "text": "1. Large sample handling capability",
            "attrs": {
                "block_label": "paragraph_title"
            },
            "level": 3
        },
        {
            "id": "p133.8",
            "order": 8,
            "type": "text",
            "bbox": {
                "l": 158.4,
                "t": 579.84,
                "r": 513.84,
                "b": 555.6
            },
            "text": "- Able to load and analyze at least three 96-well sample plates (288 samples) unattended without any user intervention or additional robotics/liquid handling requirement"
        },
        {
            "id": "p133.9",
            "order": 9,
            "type": "heading",
            "bbox": {
                "l": 124.32,
                "t": 553.2,
                "r": 349.2,
                "b": 542.88
            },
            "text": "2. Continuous illumination and detection of capillaries",
            "attrs": {
                "block_label": "paragraph_title"
            },
            "level": 3
        },
        {
            "id": "p133.10",
            "order": 10,
            "type": "list",
            "bbox": {
                "l": 158.4,
                "t": 539.76,
                "r": 526.8,
                "b": 503.28
            },
            "text": "",
            "attrs": {
                "item_count": 2
            },
            "children": [
                {
                    "id": "p133.10.1",
                    "order": 11,
                    "type": "list_item",
                    "bbox": {
                        "l": 158.64,
                        "t": 539.76,
                        "r": 526.8,
                        "b": 516.24
                    },
                    "text": "Has continuous LED illumination of the capillaries AND continuous uninterrupted detection of fluorescent signal through a CCD Detector",
                    "marker": "-"
                },
                {
                    "id": "p133.10.2",
                    "order": 12,
                    "type": "list_item",
                    "bbox": {
                        "l": 158.4,
                        "t": 513.84,
                        "r": 503.28,
                        "b": 503.28
                    },
                    "text": "Uses LED based fluorescence with excitation at 470 nm and detection at 520-580 nm",
                    "marker": "-"
                }
            ]
        },
        {
            "id": "p133.11",
            "order": 13,
            "type": "heading",
            "bbox": {
                "l": 125.28,
                "t": 500.4,
                "r": 247.44,
                "b": 489.6
            },
            "text": "3. Uninterrupted operations",
            "attrs": {
                "block_label": "paragraph_title"
            },
            "level": 3
        },
        {
            "id": "p133.12",
            "order": 14,
            "type": "text",
            "bbox": {
                "l": 149.04,
                "t": 487.2,
                "r": 528.48,
                "b": 464.4
            },
            "text": "- Able to change 96-well sample plates without the need for stopping in-progress instrument operation"
        },
        {
            "id": "p133.13",
            "order": 15,
            "type": "heading",
            "bbox": {
                "l": 125.04,
                "t": 460.8,
                "r": 296.16,
                "b": 450
            },
            "text": "4. Ability to use different capillary arrays",
            "attrs": {
                "block_label": "paragraph_title"
            },
            "level": 3
        },
        {
            "id": "p133.14",
            "order": 16,
            "type": "text",
            "bbox": {
                "l": 159.12,
                "t": 447.6,
                "r": 519.84,
                "b": 424.08
            },
            "text": "- Utilizes a capillary array format with the ability to use capillary arrays of different lengths (22cm, 33cm and 55cm)"
        },
        {
            "id": "p133.15",
            "order": 17,
            "type": "heading",
            "bbox": {
                "l": 125.28,
                "t": 421.44,
                "r": 283.2,
                "b": 410.88
            },
            "text": "5. Ability to switch between gel types",
            "attrs": {
                "block_label": "paragraph_title"
            },
            "level": 3
        },
        {
            "id": "p133.16",
            "order": 18,
            "type": "text",
            "bbox": {
                "l": 150.48,
                "t": 408.24,
                "r": 507.12,
                "b": 384.96
            },
            "text": "- Able to switch between 2 different gel/application types without stopping in-progress instrument operation"
        },
        {
            "id": "p133.17",
            "order": 19,
            "type": "heading",
            "bbox": {
                "l": 125.28,
                "t": 382.08,
                "r": 205.68,
                "b": 370.8
            },
            "text": "6. High sensitivity",
            "attrs": {
                "block_label": "paragraph_title"
            },
            "level": 3
        },
        {
            "id": "p133.18",
            "order": 20,
            "type": "text",
            "bbox": {
                "l": 159.36,
                "t": 368.64,
                "r": 530.16,
                "b": 344.88
            },
            "text": "- Has demonstrated sensitivity for fragments of at least 5 pg/μL and demonstrated resolution to 3bp for fragments under 300 bp"
        },
        {
            "id": "p133.19",
            "order": 21,
            "type": "heading",
            "bbox": {
                "l": 125.52,
                "t": 342.48,
                "r": 206.4,
                "b": 331.68
            },
            "text": "7. High resolution",
            "attrs": {
                "block_label": "paragraph_title"
            },
            "level": 3
        },
        {
            "id": "p133.20",
            "order": 22,
            "type": "text",
            "bbox": {
                "l": 157.44,
                "t": 328.8,
                "r": 391.92,
                "b": 318
            },
            "text": "- Has a sizing accuracy of[p133.20.1] and sizing precision of [p133.20.2]",
            "children": [
                {
                    "id": "p133.20.1",
                    "order": 23,
                    "type": "text",
                    "bbox": {
                        "l": 157.44,
                        "t": 328.8,
                        "r": 391.92,
                        "b": 318
                    },
                    "text": "\\leq5\\%",
                    "attrs": {
                        "inline": true,
                        "text_offset": 26,
                        "text_span": 11,
                        "bbox_estimated": true
                    }
                },
                {
                    "id": "p133.20.2",
                    "order": 24,
                    "type": "formula",
                    "bbox": {
                        "l": 157.44,
                        "t": 328.8,
                        "r": 391.92,
                        "b": 318
                    },
                    "text": "\\leq2\\%",
                    "attrs": {
                        "latex": "\\leq2\\%",
                        "inline": true,
                        "text_offset": 62,
                        "text_span": 11,
                        "bbox_estimated": true,
                        "notation": "latex",
                        "alt": "is less than or equal to 2 %",
                        "mathml": "<math aria-label=\"is less than or equal to 2 %\" xmlns=\"http://www.w3.org/1998/Math/MathML\" display=\"inline\"><mrow><mo>&#x02264;</mo><mn>2</mn><mi>&#x00025;</mi></mrow></math>"
                    }
                }
            ]
        },
        {
            "id": "p133.21",
            "order": 25,
            "type": "heading",
            "bbox": {
                "l": 125.28,
                "t": 315.36,
                "r": 273.84,
                "b": 304.8
            },
            "text": "8. A wide sample application range",
            "attrs": {
                "block_label": "paragraph_title"
            },
            "level": 3
        },
        {
            "id": "p133.22",
            "order": 26,
            "type": "list",
            "bbox": {
                "l": 157.92,
                "t": 302.64,
                "r": 532.8,
                "b": 265.68
            },
            "text": "",
            "attrs": {
                "item_count": 2
            },
            "children": [
                {
                    "id": "p133.22.1",
                    "order": 27,
                    "type": "list_item",
                    "bbox": {
                        "l": 158.64,
                        "t": 302.64,
                        "r": 358.32,
                        "b": 291.84
                    },
                    "text": "Able to use qualitative kit and quantitative kits",
                    "marker": "-"
                },
                {
                    "id": "p133.22.2",
                    "order": 28,
                    "type": "list_item",
                    "bbox": {
                        "l": 157.92,
                        "t": 289.44,
                        "r": 532.8,
                        "b": 265.68
                    },
                    "text": "Able to analyze dsDNA fragments from 35 bp to 50,000 bp, total RNA, messenger RNA, small RNAs, genomic DNA and DNA smears",
                    "marker": "-"
                }
            ]
        },
        {
            "id": "p133.23",
            "order": 29,
            "type": "heading",
            "bbox": {
                "l": 125.04,
                "t": 262.8,
                "r": 274.32,
                "b": 252.24
            },
            "text": "9. Integrated data analysis package",
            "attrs": {
                "block_label": "paragraph_title"
            },
            "level": 3
        },
        {
            "id": "p133.24",
            "order": 30,
            "type": "text",
            "bbox": {
                "l": 157.92,
                "t": 249.84,
                "r": 505.68,
                "b": 225.84
            },
            "text": "Has a data analysis software package capable of sizing, quantification, smear analysis, integrity determination and report generation"
        },
        {
            "id": "p133.25",
            "order": 31,
            "type": "heading",
            "bbox": {
                "l": 125.76,
                "t": 223.44,
                "r": 234.96,
                "b": 213.12
            },
            "text": "10. Automated operations",
            "attrs": {
                "block_label": "paragraph_title"
            },
            "level": 3
        },
        {
            "id": "p133.26",
            "order": 32,
            "type": "list",
            "bbox": {
                "l": 158.4,
                "t": 210,
                "r": 516.72,
                "b": 172.8
            },
            "text": "",
            "attrs": {
                "item_count": 2
            },
            "children": [
                {
                    "id": "p133.26.1",
                    "order": 33,
                    "type": "list_item",
                    "bbox": {
                        "l": 158.4,
                        "t": 210,
                        "r": 451.92,
                        "b": 199.2
                    },
                    "text": "Has automated flushing of the capillaries between every injection cycle",
                    "marker": "-"
                },
                {
                    "id": "p133.26.2",
                    "order": 34,
                    "type": "list_item",
                    "bbox": {
                        "l": 158.64,
                        "t": 196.8,
                        "r": 516.72,
                        "b": 172.8
                    },
                    "text": "Able to perform simultaneous, parallel injection and separation of at least 12 samples at once from a 96-well sample plate, and sample from all the wells of the plate",
                    "marker": "-"
                }
            ]
        }
    ],
    "excluded_furniture": {
        "first": [],
        "last": []
    }
}