    "document_id": 11891,
    "page": 78,
    "width_pt": 792,
    "height_pt": 612,
    "rotation": 270,
    "pipeline_version": "paddleocr-vl-1.6+paul-48",
    "engine": "paddleocr_vl",
    "source_run_id": 12003,
    "item_count": 63,
    "counts_by_type": {
        "form_field": 2,
        "header": 1,
        "table": 2,
        "table_cell": 55,
        "text": 3
    },
    "build_ms": 13,
    "items": [
        {
            "id": "p78.1",
            "order": 1,
            "type": "header",
            "bbox": {
                "l": 36.96,
                "t": 522,
                "r": 361.2,
                "b": 496.56
            },
            "text": "2026-02 Existing and Proposed NOAA 24-hr D 100-Year-Projected Rainfall=11.41\"\nPrepared by Dynamic Engineering Printed 2/10/2026\nHydroCAD® 10.20-8a s/n 08640 © 2025 HydroCAD Software Solutions LLC Page 113",
            "attrs": {
                "block_label": "header"
            },
            "level": 2
        },
        {
            "id": "p78.2",
            "order": 2,
            "type": "table",
            "bbox": {
                "l": 36.72,
                "t": 501.951861,
                "r": 360,
                "b": 104.88
            },
            "text": "",
            "attrs": {
                "block_label": "table",
                "n_rows": 26,
                "n_cols": 4,
                "integrity": {
                    "cells_checked": 42,
                    "cells_flagged": 25,
                    "flags": [
                        {
                            "row": 0,
                            "col": 0,
                            "coverage": 0,
                            "text": "Time span=0.00-72.00 hrs, dt=0.05 hrs, 1441 points"
                        },
                        {
                            "row": 1,
                            "col": 0,
                            "coverage": 0.14,
                            "text": "Runoff by SCS TR-20 method, UH=Delmarva, Weighted-CN"
                        },
                        {
                            "row": 2,
                            "col": 0,
                            "coverage": 0,
                            "text": "Reach routing by Stor-Ind+Trans method - Pond routing by St…"
                        },
                        {
                            "row": 3,
                            "col": 0,
                            "coverage": 0,
                            "text": "Subcatchment3S: Ex. Study Area West"
                        },
                        {
                            "row": 3,
                            "col": 1,
                            "coverage": 0,
                            "text": "Runoff Area=0.930 ac 0.00% Impervious Runoff Depth=2.87\""
                        },
                        {
                            "row": 4,
                            "col": 1,
                            "coverage": 0,
                            "text": "Flow Length=98' Tc=10.0 min CN=39 Runoff=1.73 cfs 0.222 af"
                        },
                        {
                            "row": 5,
                            "col": 0,
                            "coverage": 0,
                            "text": "Subcatchment4S: Ex. Study Area West"
                        },
                        {
                            "row": 5,
                            "col": 1,
                            "coverage": 0,
                            "text": "Runoff Area=0.090 ac 100.00% Impervious Runoff Depth=11.17\""
                        },
                        {
                            "row": 6,
                            "col": 1,
                            "coverage": 0.22,
                            "text": "Flow Length=248' Tc=10.0 min CN=98 Runoff=0.64 cfs 0.084 af"
                        },
                        {
                            "row": 8,
                            "col": 1,
                            "coverage": 0.2,
                            "text": "Flow Length=82' Slope=0.0150 /\" Tc=10.0 min CN=98 Runoff=0.…"
                        },
                        {
                            "row": 9,
                            "col": 0,
                            "coverage": 0.2,
                            "text": "Subcatchment7S: Ex. Study Area Road"
                        },
                        {
                            "row": 9,
                            "col": 1,
                            "coverage": 0,
                            "text": "Runoff Area=0.120 ac 0.00% Impervious Runoff Depth=2.87\""
                        }
                    ]
                }
            },
            "children": [
                {
                    "id": "p78.2.1",
                    "order": 3,
                    "type": "table_cell",
                    "bbox": {
                        "l": 36.72,
                        "t": 491.76,
                        "r": 360,
                        "b": 478.4193
                    },
                    "text": "Time span=0.00-72.00 hrs, dt=0.05 hrs, 1441 points",
                    "attrs": {
                        "row": 0,
                        "col": 0,
                        "rowspan": 1,
                        "colspan": 4
                    }
                },
                {
                    "id": "p78.2.2",
                    "order": 4,
                    "type": "table_cell",
                    "bbox": {
                        "l": 36.72,
                        "t": 478.4193,
                        "r": 360,
                        "b": 465.0786
                    },
                    "text": "Runoff by SCS TR-20 method, UH=Delmarva, Weighted-CN",
                    "attrs": {
                        "row": 1,
                        "col": 0,
                        "rowspan": 1,
                        "colspan": 4
                    }
                },
                {
                    "id": "p78.2.3",
                    "order": 5,
                    "type": "table_cell",
                    "bbox": {
                        "l": 36.72,
                        "t": 465.0786,
                        "r": 360,
                        "b": 451.7379
                    },
                    "text": "Reach routing by Stor-Ind+Trans method - Pond routing by Stor-Ind method",
                    "attrs": {
                        "row": 2,
                        "col": 0,
                        "rowspan": 1,
                        "colspan": 4
                    }
                },
                {
                    "id": "p78.2.4",
                    "order": 6,
                    "type": "table_cell",
                    "bbox": {
                        "l": 36.72,
                        "t": 451.7379,
                        "r": 117.54,
                        "b": 438.3972
                    },
                    "text": "Subcatchment3S: Ex. Study Area West",
                    "attrs": {
                        "row": 3,
                        "col": 0,
                        "rowspan": 1,
                        "colspan": 1
                    }
                },
                {
                    "id": "p78.2.5",
                    "order": 7,
                    "type": "table_cell",
                    "bbox": {
                        "l": 117.54,
                        "t": 451.7379,
                        "r": 360,
                        "b": 438.3972
                    },
                    "text": "Runoff Area=0.930 ac 0.00% Impervious Runoff Depth=2.87\"",
                    "attrs": {
                        "row": 3,
                        "col": 1,
                        "rowspan": 1,
                        "colspan": 3
                    }
                },
                {
                    "id": "p78.2.6",
                    "order": 8,
                    "type": "table_cell",
                    "bbox": {
                        "l": 36.72,
                        "t": 438.3972,
                        "r": 117.54,
                        "b": 425.0566
                    },
                    "text": "",
                    "attrs": {
                        "row": 4,
                        "col": 0,
                        "rowspan": 1,
                        "colspan": 1
                    }
                },
                {
                    "id": "p78.2.7",
                    "order": 9,
                    "type": "table_cell",
                    "bbox": {
                        "l": 117.54,
                        "t": 438.3972,
                        "r": 360,
                        "b": 425.0566
                    },
                    "text": "Flow Length=98' Tc=10.0 min CN=39 Runoff=1.73 cfs 0.222 af",
                    "attrs": {
                        "row": 4,
                        "col": 1,
                        "rowspan": 1,
                        "colspan": 3
                    }
                },
                {
                    "id": "p78.2.8",
                    "order": 10,
                    "type": "table_cell",
                    "bbox": {
                        "l": 36.72,
                        "t": 425.0566,
                        "r": 117.54,
                        "b": 411.7159
                    },
                    "text": "Subcatchment4S: Ex. Study Area West",
                    "attrs": {
                        "row": 5,
                        "col": 0,
                        "rowspan": 1,
                        "colspan": 1
                    }
                },
                {
                    "id": "p78.2.9",
                    "order": 11,
                    "type": "table_cell",
                    "bbox": {
                        "l": 117.54,
                        "t": 425.0566,
                        "r": 360,
                        "b": 411.7159
                    },
                    "text": "Runoff Area=0.090 ac 100.00% Impervious Runoff Depth=11.17\"",
                    "attrs": {
                        "row": 5,
                        "col": 1,
                        "rowspan": 1,
                        "colspan": 3
                    }
                },
                {
                    "id": "p78.2.10",
                    "order": 12,
                    "type": "table_cell",
                    "bbox": {
                        "l": 36.72,
                        "t": 411.7159,
                        "r": 117.54,
                        "b": 398.3752
                    },
                    "text": "",
                    "attrs": {
                        "row": 6,
                        "col": 0,
                        "rowspan": 1,
                        "colspan": 1
                    }
                },
                {
                    "id": "p78.2.11",
                    "order": 13,
                    "type": "table_cell",
                    "bbox": {
                        "l": 117.54,
                        "t": 411.7159,
                        "r": 360,
                        "b": 398.3752
                    },
                    "text": "Flow Length=248' Tc=10.0 min CN=98 Runoff=0.64 cfs 0.084 af",
                    "attrs": {
                        "row": 6,
                        "col": 1,
                        "rowspan": 1,
                        "colspan": 3
                    }
                },
                {
                    "id": "p78.2.12",
                    "order": 14,
                    "type": "table_cell",
                    "bbox": {
                        "l": 36.72,
                        "t": 398.3752,
                        "r": 117.54,
                        "b": 385.0345
                    },
                    "text": "Subcatchment6S: Ex. Study Area Road",
                    "attrs": {
                        "row": 7,
                        "col": 0,
                        "rowspan": 1,
                        "colspan": 1
                    }
                },
                {
                    "id": "p78.2.13",
                    "order": 15,
                    "type": "table_cell",
                    "bbox": {
                        "l": 169.602248,
                        "t": 501.951861,
                        "r": 355.187046,
                        "b": 496.10702
                    },
                    "text": "Runoff Area=0.030 ac 100.00% Impervious Runoff Depth=11.17\"",
                    "attrs": {
                        "row": 7,
                        "col": 1,
                        "rowspan": 1,
                        "colspan": 3,
                        "bbox_refit": true
                    }
                },
                {
                    "id": "p78.2.14",
                    "order": 16,
                    "type": "table_cell",
                    "bbox": {
                        "l": 36.72,
                        "t": 385.0345,
                        "r": 117.54,
                        "b": 371.6938
                    },
                    "text": "",
                    "attrs": {
                        "row": 8,
                        "col": 0,
                        "rowspan": 1,
                        "colspan": 1
                    }
                },
                {
                    "id": "p78.2.15",
                    "order": 17,
                    "type": "table_cell",
                    "bbox": {
                        "l": 117.54,
                        "t": 385.0345,
                        "r": 360,
                        "b": 371.6938
                    },
                    "text": "Flow Length=82' Slope=0.0150 /\" Tc=10.0 min CN=98 Runoff=0.21 cfs 0.028 af",
                    "attrs": {
                        "row": 8,
                        "col": 1,
                        "rowspan": 1,
                        "colspan": 3
                    }
                },
                {
                    "id": "p78.2.16",
                    "order": 18,
                    "type": "table_cell",
                    "bbox": {
                        "l": 36.72,
                        "t": 371.6938,
                        "r": 117.54,
                        "b": 358.3531
                    },
                    "text": "Subcatchment7S: Ex. Study Area Road",
                    "attrs": {
                        "row": 9,
                        "col": 0,
                        "rowspan": 1,
                        "colspan": 1
                    }
                },
                {
                    "id": "p78.2.17",
                    "order": 19,
                    "type": "table_cell",
                    "bbox": {
                        "l": 117.54,
                        "t": 371.6938,
                        "r": 360,
                        "b": 358.3531
                    },
                    "text": "Runoff Area=0.120 ac 0.00% Impervious Runoff Depth=2.87\"",
                    "attrs": {
                        "row": 9,
                        "col": 1,
                        "rowspan": 1,
                        "colspan": 3
                    }
                },
                {
                    "id": "p78.2.18",
                    "order": 20,
                    "type": "table_cell",
                    "bbox": {
                        "l": 36.72,
                        "t": 358.3531,
                        "r": 117.54,
                        "b": 345.0124
                    },
                    "text": "",
                    "attrs": {
                        "row": 10,
                        "col": 0,
                        "rowspan": 1,
                        "colspan": 1
                    }
                },
                {
                    "id": "p78.2.19",
                    "order": 21,
                    "type": "table_cell",
                    "bbox": {
                        "l": 117.54,
                        "t": 358.3531,
                        "r": 360,
                        "b": 345.0124
                    },
                    "text": "Flow Length=61' Slope=0.0100 /\" Tc=10.0 min CN=39 Runoff=0.22 cfs 0.029 af",
                    "attrs": {
                        "row": 10,
                        "col": 1,
                        "rowspan": 1,
                        "colspan": 3
                    }
                },
                {
                    "id": "p78.2.20",
                    "order": 22,
                    "type": "table_cell",
                    "bbox": {
                        "l": 36.72,
                        "t": 345.0124,
                        "r": 117.54,
                        "b": 331.6717
                    },
                    "text": "Subcatchment10S: Study Area WQ MTD",
                    "attrs": {
                        "row": 11,
                        "col": 0,
                        "rowspan": 1,
                        "colspan": 1
                    }
                },
                {
                    "id": "p78.2.21",
                    "order": 23,
                    "type": "table_cell",
                    "bbox": {
                        "l": 117.54,
                        "t": 345.0124,
                        "r": 360,
                        "b": 331.6717
                    },
                    "text": "Runoff Area=0.610 ac 100.00% Impervious Runoff Depth=11.17\"",
                    "attrs": {
                        "row": 11,
                        "col": 1,
                        "rowspan": 1,
                        "colspan": 3
                    }
                },
                {
                    "id": "p78.2.22",
                    "order": 24,
                    "type": "table_cell",
                    "bbox": {
                        "l": 36.72,
                        "t": 331.6717,
                        "r": 117.54,
                        "b": 318.331
                    },
                    "text": "",
                    "attrs": {
                        "row": 12,
                        "col": 0,
                        "rowspan": 1,
                        "colspan": 1
                    }
                },
                {
                    "id": "p78.2.23",
                    "order": 25,
                    "type": "table_cell",
                    "bbox": {
                        "l": 117.54,
                        "t": 331.6717,
                        "r": 360,
                        "b": 318.331
                    },
                    "text": "Flow Length=352' Tc=10.0 min CN=98 Runoff=4.37 cfs 0.568 af",
                    "attrs": {
                        "row": 12,
                        "col": 1,
                        "rowspan": 1,
                        "colspan": 3
                    }
                },
                {
                    "id": "p78.2.24",
                    "order": 26,
                    "type": "table_cell",
                    "bbox": {
                        "l": 36.72,
                        "t": 318.331,
                        "r": 117.54,
                        "b": 304.9903
                    },
                    "text": "Subcatchment11S: Study Area WQ MTD",
                    "attrs": {
                        "row": 13,
                        "col": 0,
                        "rowspan": 1,
                        "colspan": 1
                    }
                },
                {
                    "id": "p78.2.25",
                    "order": 27,
                    "type": "table_cell",
                    "bbox": {
                        "l": 117.54,
                        "t": 318.331,
                        "r": 360,
                        "b": 304.9903
                    },
                    "text": "Runoff Area=0.020 ac 0.00% Impervious Runoff Depth=2.87\"",
                    "attrs": {
                        "row": 13,
                        "col": 1,
                        "rowspan": 1,
                        "colspan": 3
                    }
                },
                {
                    "id": "p78.2.26",
                    "order": 28,
                    "type": "table_cell",
                    "bbox": {
                        "l": 36.72,
                        "t": 304.9903,
                        "r": 117.54,
                        "b": 291.6497
                    },
                    "text": "",
                    "attrs": {
                        "row": 14,
                        "col": 0,
                        "rowspan": 1,
                        "colspan": 1
                    }
                },
                {
                    "id": "p78.2.27",
                    "order": 29,
                    "type": "table_cell",
                    "bbox": {
                        "l": 117.54,
                        "t": 304.9903,
                        "r": 360,
                        "b": 291.6497
                    },
                    "text": "Flow Length=351' Tc=10.0 min CN=39 Runoff=0.04 cfs 0.005 af",
                    "attrs": {
                        "row": 14,
                        "col": 1,
                        "rowspan": 1,
                        "colspan": 3
                    }
                },
                {
                    "id": "p78.2.28",
                    "order": 30,
                    "type": "table_cell",
                    "bbox": {
                        "l": 36.72,
                        "t": 291.6497,
                        "r": 117.54,
                        "b": 278.309
                    },
                    "text": "Subcatchment12S: Study Area Road",
                    "attrs": {
                        "row": 15,
                        "col": 0,
                        "rowspan": 1,
                        "colspan": 1
                    }
                },
                {
                    "id": "p78.2.29",
                    "order": 31,
                    "type": "table_cell",
                    "bbox": {
                        "l": 117.54,
                        "t": 291.6497,
                        "r": 360,
                        "b": 278.309
                    },
                    "text": "Runoff Area=0.030 ac 100.00% Impervious Runoff Depth=11.17\"",
                    "attrs": {
                        "row": 15,
                        "col": 1,
                        "rowspan": 1,
                        "colspan": 3
                    }
                },
                {
                    "id": "p78.2.30",
                    "order": 32,
                    "type": "table_cell",
                    "bbox": {
                        "l": 36.72,
                        "t": 278.309,
                        "r": 117.54,
                        "b": 264.9683
                    },
                    "text": "",
                    "attrs": {
                        "row": 16,
                        "col": 0,
                        "rowspan": 1,
                        "colspan": 1
                    }
                },
                {
                    "id": "p78.2.31",
                    "order": 33,
                    "type": "table_cell",
                    "bbox": {
                        "l": 120.737635,
                        "t": 494.392564,
                        "r": 354.824727,
                        "b": 488.547723
                    },
                    "text": "Flow Length=35' Slope=0.0322 /\" Tc=10.0 min CN=98 Runoff=0.21 cfs 0.028 af",
                    "attrs": {
                        "row": 16,
                        "col": 1,
                        "rowspan": 1,
                        "colspan": 3,
                        "bbox_refit": true
                    }
                },
                {
                    "id": "p78.2.32",
                    "order": 34,
                    "type": "table_cell",
                    "bbox": {
                        "l": 36.72,
                        "t": 264.9683,
                        "r": 117.54,
                        "b": 251.6276
                    },
                    "text": "Subcatchment14S: Study Area West",
                    "attrs": {
                        "row": 17,
                        "col": 0,
                        "rowspan": 1,
                        "colspan": 1
                    }
                },
                {
                    "id": "p78.2.33",
                    "order": 35,
                    "type": "table_cell",
                    "bbox": {
                        "l": 120.737635,
                        "t": 479.27487,
                        "r": 355.255321,
                        "b": 465.871732
                    },
                    "text": "Runoff Area=0.310 ac 0.00% Impervious Runoff Depth=2.87\"\nFlow Length=48' Slope=0.0850 /\" Tc=10.0 min CN=39 Runoff=0.58 cfs 0.074 af",
                    "attrs": {
                        "row": 17,
                        "col": 1,
                        "rowspan": 1,
                        "colspan": 3,
                        "bbox_refit": true,
                        "merged_continuation": true
                    }
                },
                {
                    "id": "p78.2.34",
                    "order": 36,
                    "type": "table_cell",
                    "bbox": {
                        "l": 36.72,
                        "t": 238.2869,
                        "r": 117.54,
                        "b": 224.9462
                    },
                    "text": "Subcatchment15S: Study Area Roof",
                    "attrs": {
                        "row": 18,
                        "col": 0,
                        "rowspan": 1,
                        "colspan": 1
                    }
                },
                {
                    "id": "p78.2.35",
                    "order": 37,
                    "type": "table_cell",
                    "bbox": {
                        "l": 117.261637,
                        "t": 456.598879,
                        "r": 355.186985,
                        "b": 443.194741
                    },
                    "text": "Runoff Area=0.110 ac 100.00% Impervious Runoff Depth=11.17\"\nFlow Length=207' Slope=0.0100 /\" Tc=10.0 min CN=98 Runoff=0.79 cfs 0.102 af",
                    "attrs": {
                        "row": 18,
                        "col": 1,
                        "rowspan": 1,
                        "colspan": 3,
                        "bbox_refit": true,
                        "merged_continuation": true
                    }
                },
                {
                    "id": "p78.2.36",
                    "order": 38,
                    "type": "table_cell",
                    "bbox": {
                        "l": 36.72,
                        "t": 211.6055,
                        "r": 117.54,
                        "b": 198.2648
                    },
                    "text": "Subcatchment19S: Study Area Road",
                    "attrs": {
                        "row": 19,
                        "col": 0,
                        "rowspan": 1,
                        "colspan": 1
                    }
                },
                {
                    "id": "p78.2.37",
                    "order": 39,
                    "type": "table_cell",
                    "bbox": {
                        "l": 120.737635,
                        "t": 433.921888,
                        "r": 355.256078,
                        "b": 420.51875
                    },
                    "text": "Runoff Area=0.090 ac 0.00% Impervious Runoff Depth=2.87\"\nFlow Length=58' Slope=0.0300 /\" Tc=10.0 min CN=39 Runoff=0.17 cfs 0.022 af",
                    "attrs": {
                        "row": 19,
                        "col": 1,
                        "rowspan": 1,
                        "colspan": 3,
                        "bbox_refit": true,
                        "merged_continuation": true
                    }
                },
                {
                    "id": "p78.2.38",
                    "order": 40,
                    "type": "table_cell",
                    "bbox": {
                        "l": 39.515301,
                        "t": 411.117905,
                        "r": 166.893889,
                        "b": 404.758103
                    },
                    "text": "Pond 21P: Basin A Routing (StormBrixx)",
                    "attrs": {
                        "row": 20,
                        "col": 0,
                        "rowspan": 1,
                        "colspan": 2,
                        "bbox_refit": true
                    }
                },
                {
                    "id": "p78.2.39",
                    "order": 41,
                    "type": "table_cell",
                    "bbox": {
                        "l": 198.36,
                        "t": 184.9241,
                        "r": 360,
                        "b": 171.5834
                    },
                    "text": "Peak Elev=120.00' Storage=7,267 cf Inflow=5.20 cfs 0.675 af Discarded=0.71 cfs 0.572 af Primary=0.91 cfs 0.103 af Outflow=1.62 cfs 0.675 af",
                    "attrs": {
                        "row": 20,
                        "col": 1,
                        "rowspan": 1,
                        "colspan": 2
                    }
                },
                {
                    "id": "p78.2.40",
                    "order": 42,
                    "type": "table_cell",
                    "bbox": {
                        "l": 39.515301,
                        "t": 388.440914,
                        "r": 150.553273,
                        "b": 382.081112
                    },
                    "text": "Link 5L: Ex Study Area West (Total)",
                    "attrs": {
                        "row": 21,
                        "col": 0,
                        "rowspan": 1,
                        "colspan": 2,
                        "bbox_refit": true
                    }
                },
                {
                    "id": "p78.2.41",
                    "order": 43,
                    "type": "table_cell",
                    "bbox": {
                        "l": 283.55457,
                        "t": 388.568906,
                        "r": 356.289199,
                        "b": 375.165769
                    },
                    "text": "Inflow=2.37 cfs 0.306 af Primary=2.37 cfs 0.306 af",
                    "attrs": {
                        "row": 21,
                        "col": 1,
                        "rowspan": 1,
                        "colspan": 2,
                        "bbox_refit": true
                    }
                },
                {
                    "id": "p78.2.42",
                    "order": 44,
                    "type": "table_cell",
                    "bbox": {
                        "l": 39.515301,
                        "t": 365.764923,
                        "r": 168.698766,
                        "b": 359.405121
                    },
                    "text": "Link 8L: Existing Study Area Road (Total)",
                    "attrs": {
                        "row": 22,
                        "col": 0,
                        "rowspan": 1,
                        "colspan": 2,
                        "bbox_refit": true
                    }
                },
                {
                    "id": "p78.2.43",
                    "order": 45,
                    "type": "table_cell",
                    "bbox": {
                        "l": 283.55457,
                        "t": 365.892915,
                        "r": 356.289611,
                        "b": 352.488778
                    },
                    "text": "Inflow=0.44 cfs 0.057 af Primary=0.44 cfs 0.057 af",
                    "attrs": {
                        "row": 22,
                        "col": 1,
                        "rowspan": 1,
                        "colspan": 2,
                        "bbox_refit": true
                    }
                },
                {
                    "id": "p78.2.44",
                    "order": 46,
                    "type": "table_cell",
                    "bbox": {
                        "l": 39.515301,
                        "t": 343.088932,
                        "r": 211.476214,
                        "b": 336.72913
                    },
                    "text": "Link 10L: Study Area Study Area WQ MTD A-110 (Total)",
                    "attrs": {
                        "row": 23,
                        "col": 0,
                        "rowspan": 1,
                        "colspan": 2,
                        "bbox_refit": true
                    }
                },
                {
                    "id": "p78.2.45",
                    "order": 47,
                    "type": "table_cell",
                    "bbox": {
                        "l": 283.55457,
                        "t": 343.215924,
                        "r": 356.289611,
                        "b": 329.812787
                    },
                    "text": "Inflow=4.41 cfs 0.573 af Primary=4.41 cfs 0.573 af",
                    "attrs": {
                        "row": 23,
                        "col": 1,
                        "rowspan": 1,
                        "colspan": 2,
                        "bbox_refit": true
                    }
                },
                {
                    "id": "p78.2.46",
                    "order": 48,
                    "type": "table_cell",
                    "bbox": {
                        "l": 39.515301,
                        "t": 320.411941,
                        "r": 144.353818,
                        "b": 314.052139
                    },
                    "text": "Link 14L: Study Area West (Total)",
                    "attrs": {
                        "row": 24,
                        "col": 0,
                        "rowspan": 1,
                        "colspan": 2,
                        "bbox_refit": true
                    }
                },
                {
                    "id": "p78.2.47",
                    "order": 49,
                    "type": "table_cell",
                    "bbox": {
                        "l": 283.55457,
                        "t": 320.539933,
                        "r": 356.289611,
                        "b": 307.135796
                    },
                    "text": "Inflow=1.22 cfs 0.177 af Primary=1.22 cfs 0.177 af",
                    "attrs": {
                        "row": 24,
                        "col": 1,
                        "rowspan": 1,
                        "colspan": 2,
                        "bbox_refit": true
                    }
                },
                {
                    "id": "p78.2.48",
                    "order": 50,
                    "type": "table_cell",
                    "bbox": {
                        "l": 39.515301,
                        "t": 297.73595,
                        "r": 152.744044,
                        "b": 291.376148
                    },
                    "text": "Link 16L: Study Area Basin A (Total)",
                    "attrs": {
                        "row": 25,
                        "col": 0,
                        "rowspan": 1,
                        "colspan": 2,
                        "bbox_refit": true
                    }
                },
                {
                    "id": "p78.2.49",
                    "order": 51,
                    "type": "table_cell",
                    "bbox": {
                        "l": 283.55457,
                        "t": 297.862943,
                        "r": 356.289611,
                        "b": 284.459805
                    },
                    "text": "Inflow=5.20 cfs 0.675 af Primary=5.20 cfs 0.675 af",
                    "attrs": {
                        "row": 25,
                        "col": 1,
                        "rowspan": 1,
                        "colspan": 2,
                        "bbox_refit": true
                    }
                }
            ]
        },
        {
            "id": "p78.3",
            "order": 52,
            "type": "table",
            "bbox": {
                "l": 432.96,
                "t": 522.48,
                "r": 756.48,
                "b": 496.32
            },
            "text": "",
            "attrs": {
                "block_label": "table",
                "n_rows": 3,
                "n_cols": 2,
                "integrity": {
                    "skipped": "no_text_layer"
                }
            },
            "children": [
                {
                    "id": "p78.3.1",
                    "order": 53,
                    "type": "table_cell",
                    "bbox": {
                        "l": 432.96,
                        "t": 522.48,
                        "r": 594.72,
                        "b": 513.76
                    },
                    "text": "2026-02 Existing and Proposed",
                    "attrs": {
                        "row": 0,
                        "col": 0,
                        "rowspan": 1,
                        "colspan": 1,
                        "column_header": true,
                        "header_source": "heuristic"
                    }
                },
                {
                    "id": "p78.3.2",
                    "order": 54,
                    "type": "table_cell",
                    "bbox": {
                        "l": 594.72,
                        "t": 522.48,
                        "r": 756.48,
                        "b": 513.76
                    },
                    "text": "NOAA 24-hr D 100-Year-Projected Rainfall=11.41\"",
                    "attrs": {
                        "row": 0,
                        "col": 1,
                        "rowspan": 1,
                        "colspan": 1,
                        "column_header": true,
                        "header_source": "heuristic"
                    }
                },
                {
                    "id": "p78.3.3",
                    "order": 55,
                    "type": "table_cell",
                    "bbox": {
                        "l": 432.96,
                        "t": 513.76,
                        "r": 594.72,
                        "b": 505.04
                    },
                    "text": "Prepared by Dynamic Engineering",
                    "attrs": {
                        "row": 1,
                        "col": 0,
                        "rowspan": 1,
                        "colspan": 1
                    }
                },
                {
                    "id": "p78.3.4",
                    "order": 56,
                    "type": "table_cell",
                    "bbox": {
                        "l": 594.72,
                        "t": 513.76,
                        "r": 756.48,
                        "b": 505.04
                    },
                    "text": "Printed 2/10/2026",
                    "attrs": {
                        "row": 1,
                        "col": 1,
                        "rowspan": 1,
                        "colspan": 1
                    }
                },
                {
                    "id": "p78.3.5",
                    "order": 57,
                    "type": "table_cell",
                    "bbox": {
                        "l": 432.96,
                        "t": 505.04,
                        "r": 594.72,
                        "b": 496.32
                    },
                    "text": "HydroCAD ○ledR 10.20-8a s/n 08640 ○ledR 2025 HydroCAD Software Solutions LLC",
                    "attrs": {
                        "row": 2,
                        "col": 0,
                        "rowspan": 1,
                        "colspan": 1
                    },
                    "children": [
                        {
                            "id": "p78.3.5.1",
                            "order": 58,
                            "type": "form_field",
                            "bbox": {
                                "l": 452.12,
                                "t": 505.04,
                                "r": 460.84,
                                "b": 496.32
                            },
                            "text": "",
                            "attrs": {
                                "field_kind": "radio",
                                "label": "ledR 10.20-8a s/n 08640",
                                "source": "glyph_estimate",
                                "bbox_estimated": true,
                                "row": 2,
                                "col": 0,
                                "rowspan": 1,
                                "colspan": 1,
                                "label_source": "parent_text",
                                "label_ref": "p78.3.5",
                                "text_offset": 9,
                                "text_span": 1
                            }
                        },
                        {
                            "id": "p78.3.5.2",
                            "order": 59,
                            "type": "form_field",
                            "bbox": {
                                "l": 505.33,
                                "t": 505.04,
                                "r": 514.05,
                                "b": 496.32
                            },
                            "text": "",
                            "attrs": {
                                "field_kind": "radio",
                                "label": "ledR 2025 HydroCAD Software Solutions LLC",
                                "source": "glyph_estimate",
                                "bbox_estimated": true,
                                "row": 2,
                                "col": 0,
                                "rowspan": 1,
                                "colspan": 1,
                                "label_source": "parent_text",
                                "label_ref": "p78.3.5",
                                "text_offset": 34,
                                "text_span": 1
                            }
                        }
                    ]
                },
                {
                    "id": "p78.3.6",
                    "order": 60,
                    "type": "table_cell",
                    "bbox": {
                        "l": 594.72,
                        "t": 505.04,
                        "r": 756.48,
                        "b": 496.32
                    },
                    "text": "Page 114",
                    "attrs": {
                        "row": 2,
                        "col": 1,
                        "rowspan": 1,
                        "colspan": 1
                    }
                }
            ]
        },
        {
            "id": "p78.4",
            "order": 61,
            "type": "text",
            "bbox": {
                "l": 432.24,
                "t": 490.56,
                "r": 754.56,
                "b": 480.24
            },
            "text": "Link 18L: Study Area Road Undetained (Total) Inflow=0.38 cfs 0.049 af"
        },
        {
            "id": "p78.5",
            "order": 62,
            "type": "text",
            "bbox": {
                "l": 679.68,
                "t": 489.6,
                "r": 754.56,
                "b": 474
            },
            "text": "Inflow=0.38 cfs 0.049 af Primary=0.38 cfs 0.049 af"
        },
        {
            "id": "p78.6",
            "order": 63,
            "type": "text",
            "bbox": {
                "l": 482.4,
                "t": 467.76,
                "r": 762.96,
                "b": 450.24
            },
            "text": "Total Runoff Area = 2.340 ac Runoff Volume = 1.161 af Average Runoff Depth = 5.95\"\n62.82% Pervious = 1.470 ac 37.18% Impervious = 0.870 ac"
        }
    ],
    "excluded_furniture": {
        "first": [],
        "last": []
    }
}