{
    "document_id": 11891,
    "page": 76,
    "width_pt": 792,
    "height_pt": 612,
    "rotation": 270,
    "pipeline_version": "paddleocr-vl-1.6+paul-48",
    "engine": "paddleocr_vl",
    "source_run_id": 12003,
    "item_count": 15,
    "counts_by_type": {
        "caption": 2,
        "figure": 2,
        "footnote": 1,
        "header": 2,
        "heading": 1,
        "table": 1,
        "table_cell": 4,
        "text": 2
    },
    "build_ms": 2,
    "items": [
        {
            "id": "p76.1",
            "order": 1,
            "type": "header",
            "bbox": {
                "l": 37.44,
                "t": 521.76,
                "r": 360.96,
                "b": 496.8
            },
            "text": "2026-02 Existing and Proposed NOAA 24-hr D 100-Year-Current Rainfall=9.48\"\nPrepared by Dynamic Engineering Printed 2/10/2026\nHydroCAD® 10.20-8a s/n 08640 © 2025 HydroCAD Software Solutions LLC Page 109",
            "attrs": {
                "block_label": "header"
            },
            "level": 2
        },
        {
            "id": "p76.2",
            "order": 2,
            "type": "header",
            "bbox": {
                "l": 433.2,
                "t": 522,
                "r": 756.48,
                "b": 496.8
            },
            "text": "2026-02 Existing and Proposed NOAA 24-hr D 100-Year-Current Rainfall=9.48\"\nPrepared by Dynamic Engineering Printed 2/10/2026\nHydroCAD® 10.20-8a s/n 08640 © 2025 HydroCAD Software Solutions LLC Page 110",
            "attrs": {
                "block_label": "header"
            },
            "level": 2
        },
        {
            "id": "p76.3",
            "order": 3,
            "type": "heading",
            "bbox": {
                "l": 71.52,
                "t": 489.6,
                "r": 334.56,
                "b": 479.76
            },
            "text": "Summary for Link 10L: Study Area Study Area WQ MTD A-110 (Total)",
            "attrs": {
                "block_label": "paragraph_title"
            },
            "level": 3
        },
        {
            "id": "p76.4",
            "order": 4,
            "type": "text",
            "bbox": {
                "l": 36,
                "t": 472.32,
                "r": 349.92,
                "b": 410.88
            },
            "text": "Inflow Area = 0.630 ac, 96.83% Impervious, Inflow Depth = 9.00\" for 100-Year-Current event\nInflow = 3.65 cfs @ 12.19 hrs, Volume = 0.473 af\nPrimary = 3.65 cfs @ 12.19 hrs, Volume = 0.473 af, Atten = 0%, Lag = 0.0 min\nRouted to Link 16L : Study Area Basin A (Total)\nPrimary outflow = Inflow, Time Span = 0.00-72.00 hrs, dt = 0.05 hrs\nFixed water surface Elevation= 117.75'"
        },
        {
            "id": "p76.5",
            "order": 5,
            "type": "caption",
            "bbox": {
                "l": 96.72,
                "t": 403.2,
                "r": 307.68,
                "b": 393.84
            },
            "text": "Link 10L: Study Area Study Area WQ MTD A-110 (Total)",
            "attrs": {
                "block_label": "figure_title"
            }
        },
        {
            "id": "p76.6",
            "order": 6,
            "type": "figure",
            "bbox": {
                "l": 45.12,
                "t": 389.52,
                "r": 352.8,
                "b": 227.28
            },
            "text": "",
            "attrs": {
                "kind": "chart",
                "block_label": "chart"
            }
        },
        {
            "id": "p76.7",
            "order": 7,
            "type": "table",
            "bbox": {
                "l": 430.8,
                "t": 520.8,
                "r": 751.92,
                "b": 443.76
            },
            "text": "",
            "attrs": {
                "block_label": "table",
                "n_rows": 4,
                "n_cols": 1,
                "integrity": {
                    "cells_checked": 4,
                    "cells_flagged": 4,
                    "flags": [
                        {
                            "row": 0,
                            "col": 0,
                            "coverage": 0,
                            "text": "Summary for Link 14L: Study Area West (Total)"
                        },
                        {
                            "row": 1,
                            "col": 0,
                            "coverage": 0,
                            "text": "Inflow Area = 1.050 ac, 68.57% Impervious, Inflow Depth = 1…"
                        },
                        {
                            "row": 2,
                            "col": 0,
                            "coverage": 0,
                            "text": "Inflow = 0.80 cfs @ 12.63 hrs, Volume= 0.099 af"
                        },
                        {
                            "row": 3,
                            "col": 0,
                            "coverage": 0,
                            "text": "Primary = 0.80 cfs @ 12.63 hrs, Volume= 0.099 af, Atten= 0%…"
                        }
                    ]
                }
            },
            "children": [
                {
                    "id": "p76.7.1",
                    "order": 8,
                    "type": "table_cell",
                    "bbox": {
                        "l": 430.8,
                        "t": 520.8,
                        "r": 751.92,
                        "b": 501.54
                    },
                    "text": "Summary for Link 14L: Study Area West (Total)",
                    "attrs": {
                        "row": 0,
                        "col": 0,
                        "rowspan": 1,
                        "colspan": 1
                    }
                },
                {
                    "id": "p76.7.2",
                    "order": 9,
                    "type": "table_cell",
                    "bbox": {
                        "l": 430.8,
                        "t": 501.54,
                        "r": 751.92,
                        "b": 482.28
                    },
                    "text": "Inflow Area = 1.050 ac, 68.57% Impervious, Inflow Depth = 1.14\" for 100-Year-Current event",
                    "attrs": {
                        "row": 1,
                        "col": 0,
                        "rowspan": 1,
                        "colspan": 1
                    }
                },
                {
                    "id": "p76.7.3",
                    "order": 10,
                    "type": "table_cell",
                    "bbox": {
                        "l": 430.8,
                        "t": 482.28,
                        "r": 751.92,
                        "b": 463.02
                    },
                    "text": "Inflow = 0.80 cfs @ 12.63 hrs, Volume= 0.099 af",
                    "attrs": {
                        "row": 2,
                        "col": 0,
                        "rowspan": 1,
                        "colspan": 1
                    }
                },
                {
                    "id": "p76.7.4",
                    "order": 11,
                    "type": "table_cell",
                    "bbox": {
                        "l": 430.8,
                        "t": 463.02,
                        "r": 751.92,
                        "b": 443.76
                    },
                    "text": "Primary = 0.80 cfs @ 12.63 hrs, Volume= 0.099 af, Atten= 0%, Lag= 0.0 min",
                    "attrs": {
                        "row": 3,
                        "col": 0,
                        "rowspan": 1,
                        "colspan": 1
                    }
                }
            ]
        },
        {
            "id": "p76.8",
            "order": 12,
            "type": "text",
            "bbox": {
                "l": 433.44,
                "t": 442.32,
                "r": 634.56,
                "b": 433.2
            },
            "text": "Primary outflow = Inflow, Time Span = 0.00-72.00 hrs, dt = 0.05 hrs"
        },
        {
            "id": "p76.9",
            "order": 13,
            "type": "caption",
            "bbox": {
                "l": 531.6,
                "t": 426.48,
                "r": 660,
                "b": 416.4
            },
            "text": "Link 14L: Study Area West (Total)",
            "attrs": {
                "block_label": "figure_title"
            }
        },
        {
            "id": "p76.10",
            "order": 14,
            "type": "figure",
            "bbox": {
                "l": 438.96,
                "t": 412.32,
                "r": 747.36,
                "b": 245.04
            },
            "text": "",
            "attrs": {
                "kind": "chart",
                "block_label": "chart"
            }
        },
        {
            "id": "p76.11",
            "order": 15,
            "type": "footnote",
            "bbox": {
                "l": 59.04,
                "t": 233.52,
                "r": 308.4,
                "b": 222.72
            },
            "text": "0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 Time (hours)",
            "attrs": {
                "block_label": "vision_footnote"
            }
        }
    ],
    "excluded_furniture": {
        "first": [],
        "last": []
    }
}