            "text": "C. For undivided major and secondary highways, one twelve (12) foot lane in the center will be clear of water for a 10-year storm peak runoff. For divided highways, one ten (10) foot lane in each direction will be clear of water for the peak runoff from a 10-year storm at ultimate development conditions (see Figure V-3). Subdivisions adjacent to highways with pre-existing flooding will be considered on a case-by-case basis."
        },
        {
            "id": "p82.2",
            "order": 2,
            "type": "text",
            "bbox": {
                "l": 104.64,
                "t": 572.64,
                "r": 564.24,
                "b": 507.84
            },
            "text": "If a storm drain is required to meet any of the three conditions listed above, it shall be designed for a minimum capacity of the peak flow from a 10-year storm. If a master planned storm drainage facility is proposed through the project which would mitigate the flooding, the developer may be required to construct the facility."
        },
        {
            "id": "p82.3",
            "order": 3,
            "type": "heading",
            "bbox": {
                "l": 68.4,
                "t": 494.4,
                "r": 461.76,
                "b": 478.56
            },
            "text": "B. HYDROLOGIC DESIGN STANDARDS AND PROCEDURES",
            "attrs": {
                "block_label": "paragraph_title"
            },
            "level": 3
        },
        {
            "id": "p82.4",
            "order": 4,
            "type": "text",
            "bbox": {
                "l": 104.88,
                "t": 462.48,
                "r": 562.8,
                "b": 430.56
            },
            "text": "The design of all master and local facilities will be in accordance with the following standards and procedures:"
        },
        {
            "id": "p82.5",
            "order": 5,
            "type": "list",
            "bbox": {
                "l": 105.12,
                "t": 415.2,
                "r": 564.24,
                "b": 100.08
            },
            "text": "",
            "attrs": {
                "item_count": 5
            },
            "children": [
                {
                    "id": "p82.5.1",
                    "order": 6,
                    "type": "list_item",
                    "bbox": {
                        "l": 105.12,
                        "t": 415.2,
                        "r": 564.24,
                        "b": 336.96
                    },
                    "text": "Hydrologic calculations will be performed in accordance with the Los Angeles County Department of Public Works Hydrology Manual except the initial time of concentration will be determined from Figure V-4 and used in the subsequent calculations. Figure V-4 may be used, subject to the limitations of length and area.",
                    "marker": "1."
                },
                {
                    "id": "p82.5.2",
                    "order": 7,
                    "type": "list_item",
                    "bbox": {
                        "l": 105.36,
                        "t": 322.08,
                        "r": 563.04,
                        "b": 291.12
                    },
                    "text": "Design frequencies will be as described under \"Hydrologic Protection Levels\".",
                    "marker": "2."
                },
                {
                    "id": "p82.5.3",
                    "order": 8,
                    "type": "list_item",
                    "bbox": {
                        "l": 105.36,
                        "t": 274.56,
                        "r": 563.52,
                        "b": 243.12
                    },
                    "text": "Where applicable, the design shall include provisions for future extension of the drainage system to serve the entire drainage basin.",
                    "marker": "3."
                },
                {
                    "id": "p82.5.4",
                    "order": 9,
                    "type": "list_item",
                    "bbox": {
                        "l": 105.6,
                        "t": 227.28,
                        "r": 392.4,
                        "b": 210.96
                    },
                    "text": "Required submittals - Improvement Plan Stage",
                    "marker": "4.",
                    "attrs": {
                        "block_label": "paragraph_title"
                    }
                },
                {
                    "id": "p82.5.5",
                    "order": 10,
                    "type": "list_item",
                    "bbox": {
                        "l": 139.92,
                        "t": 195.36,
                        "r": 563.52,
                        "b": 100.08
                    },
                    "text": "Hydrology map on a scale of 1:500 or larger (e.g. 1:200) showing the entire drainage area tributary to a master plan drainage facility or a regional drainage facility. It will show the entire tributary area with contours/elevations, drainage area sizes, catch basins, connector pipes, mainline pipes, and the pertinent discharge data. Appropriate soil classifications and land use information will also be submitted.",