    "document_id": 11428,
    "page": 81,
    "width_pt": 612,
    "height_pt": 792,
    "rotation": 0,
    "pipeline_version": "paddleocr-vl-1.6+paul-48",
    "engine": "paddleocr_vl",
    "source_run_id": 11539,
    "item_count": 18,
    "counts_by_type": {
        "figure": 1,
        "header": 1,
        "heading": 1,
        "list": 2,
        "list_item": 12,
        "text": 1
    },
    "build_ms": 1,
    "items": [
        {
            "id": "p81.1",
            "order": 1,
            "type": "header",
            "bbox": {
                "l": 234.96,
                "t": 792,
                "r": 356.88,
                "b": 785.52
            },
            "text": "",
            "attrs": {
                "block_label": "header"
            },
            "level": 2
        },
        {
            "id": "p81.2",
            "order": 2,
            "type": "figure",
            "bbox": {
                "l": 11.52,
                "t": 719.52,
                "r": 41.28,
                "b": 689.76
            },
            "text": "",
            "attrs": {
                "role": "page_header",
                "block_label": "header_image"
            }
        },
        {
            "id": "p81.3",
            "order": 3,
            "type": "heading",
            "bbox": {
                "l": 67.92,
                "t": 701.52,
                "r": 347.52,
                "b": 685.44
            },
            "text": "A. HYDROLOGIC PROTECTION LEVELS",
            "attrs": {
                "block_label": "paragraph_title"
            },
            "level": 3
        },
        {
            "id": "p81.4",
            "order": 4,
            "type": "list",
            "bbox": {
                "l": 104.16,
                "t": 653.76,
                "r": 564.96,
                "b": 211.68
            },
            "text": "",
            "attrs": {
                "item_count": 10
            },
            "children": [
                {
                    "id": "p81.4.1",
                    "order": 5,
                    "type": "list_item",
                    "bbox": {
                        "l": 104.4,
                        "t": 653.76,
                        "r": 564.96,
                        "b": 605.28
                    },
                    "text": "Capital Flood Protection (based on runoff resulting from a rainfall with a probability of occurrence of once in 50 years). The following shall be designed for the Capital Flood:",
                    "marker": "1."
                },
                {
                    "id": "p81.4.2",
                    "order": 6,
                    "type": "list_item",
                    "bbox": {
                        "l": 139.2,
                        "t": 590.16,
                        "r": 564,
                        "b": 557.52
                    },
                    "text": "All regional facilities as described in the City of Palmdale Drainage Master Plan or as modified by the City Engineer.",
                    "marker": "a."
                },
                {
                    "id": "p81.4.3",
                    "order": 7,
                    "type": "list_item",
                    "bbox": {
                        "l": 139.92,
                        "t": 543.36,
                        "r": 296.88,
                        "b": 527.28
                    },
                    "text": "Natural Watercourses",
                    "marker": "b."
                },
                {
                    "id": "p81.4.4",
                    "order": 8,
                    "type": "list_item",
                    "bbox": {
                        "l": 139.92,
                        "t": 510.72,
                        "r": 563.76,
                        "b": 464.4
                    },
                    "text": "Open channels, closed conduits, bridges, dams, detention basins and debris basins which are constructed in or intercept flow from natural watercourses.",
                    "marker": "c."
                },
                {
                    "id": "p81.4.5",
                    "order": 9,
                    "type": "list_item",
                    "bbox": {
                        "l": 139.92,
                        "t": 449.28,
                        "r": 241.92,
                        "b": 432.24
                    },
                    "text": "Floodways.",
                    "marker": "d."
                },
                {
                    "id": "p81.4.6",
                    "order": 10,
                    "type": "list_item",
                    "bbox": {
                        "l": 138.96,
                        "t": 417.12,
                        "r": 563.52,
                        "b": 384.96
                    },
                    "text": "Natural depressions or sumps. Secondary overflow will be provided for all sump areas.",
                    "marker": "e."
                },
                {
                    "id": "p81.4.7",
                    "order": 11,
                    "type": "list_item",
                    "bbox": {
                        "l": 139.68,
                        "t": 370.8,
                        "r": 534,
                        "b": 337.44
                    },
                    "text": "Culverts under arterial highways, except interim low flow culverts constructed for the purpose of eliminating cross gutters.",
                    "marker": "f."
                },
                {
                    "id": "p81.4.8",
                    "order": 12,
                    "type": "list_item",
                    "bbox": {
                        "l": 138.96,
                        "t": 323.04,
                        "r": 564.48,
                        "b": 276
                    },
                    "text": "The lowest finish floor elevation of all habitable structures shall be a minimum of one-foot above the maximum water level resulting from a Capital Flood.",
                    "marker": "g."
                },
                {
                    "id": "p81.4.9",
                    "order": 13,
                    "type": "list_item",
                    "bbox": {
                        "l": 104.16,
                        "t": 261.12,
                        "r": 286.08,
                        "b": 244.56
                    },
                    "text": "25-Year and 10-Year Storm",
                    "marker": "2.",
                    "attrs": {
                        "block_label": "paragraph_title"
                    }
                },
                {
                    "id": "p81.4.10",
                    "order": 14,
                    "type": "list_item",
                    "bbox": {
                        "l": 104.88,
                        "t": 228.96,
                        "r": 523.68,
                        "b": 211.68
                    },
                    "text": "All master plan and local drainage facilities will generally be designed so that:"
                }
            ]
        },
        {
            "id": "p81.5",
            "order": 15,
            "type": "list",
            "bbox": {
                "l": 132.48,
                "t": 197.04,
                "r": 563.76,
                "b": 117.84
            },
            "text": "",
            "attrs": {
                "item_count": 2
            },
            "children": [
                {
                    "id": "p81.5.1",
                    "order": 16,
                    "type": "list_item",
                    "bbox": {
                        "l": 132.48,
                        "t": 197.04,
                        "r": 563.76,
                        "b": 164.64
                    },
                    "text": "The peak runoff from a 25-year storm will be contained within the street right-of-way (see Figure V-1).",
                    "marker": "a."
                },
                {
                    "id": "p81.5.2",
                    "order": 17,
                    "type": "list_item",
                    "bbox": {
                        "l": 132.72,
                        "t": 150,
                        "r": 563.52,
                        "b": 117.84
                    },
                    "text": "The peak runoff from a 10-year storm will be contained at or below the street curbs (see Figure V-2).",
                    "marker": "b."
                }
            ]
        },
        {
            "id": "p81.6",
            "order": 18,
            "type": "text",
            "bbox": {
                "l": 300.72,
                "t": 85.44,
                "r": 332.64,
                "b": 72
            },
            "text": "V-2",
            "attrs": {
                "block_label": "number"
            }
        }
    ],
    "excluded_furniture": {
        "first": [],
        "last": []
    }
}