    "document_id": 11428,
    "page": 198,
    "width_pt": 612,
    "height_pt": 792,
    "rotation": 0,
    "pipeline_version": "paddleocr-vl-1.6+paul-48",
    "engine": "paddleocr_vl",
    "source_run_id": 11539,
    "item_count": 17,
    "counts_by_type": {
        "table": 1,
        "table_cell": 16
    },
    "build_ms": 0,
    "items": [
        {
            "id": "p198.1",
            "order": 1,
            "type": "table",
            "bbox": {
                "l": 70.8,
                "t": 773.04,
                "r": 594,
                "b": 32.4
            },
            "text": "",
            "attrs": {
                "block_label": "table",
                "n_rows": 14,
                "n_cols": 2
            },
            "children": [
                {
                    "id": "p198.1.1",
                    "order": 2,
                    "type": "table_cell",
                    "bbox": {
                        "l": 70.8,
                        "t": 773.04,
                        "r": 594,
                        "b": 720.1371
                    },
                    "text": "DETENTION/RETENTION BASIN NOTES (continued)",
                    "attrs": {
                        "row": 0,
                        "col": 0,
                        "rowspan": 1,
                        "colspan": 2
                    }
                },
                {
                    "id": "p198.1.2",
                    "order": 3,
                    "type": "table_cell",
                    "bbox": {
                        "l": 70.8,
                        "t": 720.1371,
                        "r": 594,
                        "b": 667.2343
                    },
                    "text": "4. Slopes within the basin and slopes outside the landscape maintenance assessment district may be as steep as 2:1 at the discretion of the City Engineer.",
                    "attrs": {
                        "row": 1,
                        "col": 0,
                        "rowspan": 1,
                        "colspan": 2
                    }
                },
                {
                    "id": "p198.1.3",
                    "order": 4,
                    "type": "table_cell",
                    "bbox": {
                        "l": 70.8,
                        "t": 667.2343,
                        "r": 594,
                        "b": 614.3314
                    },
                    "text": "5. Pipe shall be encased per STD Plan D-6.",
                    "attrs": {
                        "row": 2,
                        "col": 0,
                        "rowspan": 1,
                        "colspan": 2
                    }
                },
                {
                    "id": "p198.1.4",
                    "order": 5,
                    "type": "table_cell",
                    "bbox": {
                        "l": 70.8,
                        "t": 614.3314,
                        "r": 594,
                        "b": 561.4286
                    },
                    "text": "6. Trench backfill (including irrigation line trenches) shall be compacted to 90% relative compaction and certified by the soils engineer. Alternatively, trenches may be backfilled with a sand-cement slurry (2 sack mix) or Portland Cement Concrete, upon the recommendation of the geotechnical consultant. Inspection of this operation by the geotechnical consultant and the city inspector is required.",
                    "attrs": {
                        "row": 3,
                        "col": 0,
                        "rowspan": 1,
                        "colspan": 2
                    }
                },
                {
                    "id": "p198.1.5",
                    "order": 6,
                    "type": "table_cell",
                    "bbox": {
                        "l": 70.8,
                        "t": 561.4286,
                        "r": 594,
                        "b": 508.5257
                    },
                    "text": "7. Soils engineer shall verify and approve trench bottom soil prior to placement of pipe.",
                    "attrs": {
                        "row": 4,
                        "col": 0,
                        "rowspan": 1,
                        "colspan": 2
                    }
                },
                {
                    "id": "p198.1.6",
                    "order": 7,
                    "type": "table_cell",
                    "bbox": {
                        "l": 70.8,
                        "t": 508.5257,
                        "r": 594,
                        "b": 455.6229
                    },
                    "text": "C. OUTLET STRUCTURES",
                    "attrs": {
                        "row": 5,
                        "col": 0,
                        "rowspan": 1,
                        "colspan": 2
                    }
                },
                {
                    "id": "p198.1.7",
                    "order": 8,
                    "type": "table_cell",
                    "bbox": {
                        "l": 70.8,
                        "t": 455.6229,
                        "r": 594,
                        "b": 402.72
                    },
                    "text": "1. The drain pipe encasement shall be placed on a firm foundation approved by the soils engineer.",
                    "attrs": {
                        "row": 6,
                        "col": 0,
                        "rowspan": 1,
                        "colspan": 2
                    }
                },
                {
                    "id": "p198.1.8",
                    "order": 9,
                    "type": "table_cell",
                    "bbox": {
                        "l": 70.8,
                        "t": 402.72,
                        "r": 594,
                        "b": 349.8171
                    },
                    "text": "2. Anti-seep collars are required at 15' intervals for pipe under the embankment, with a minimum of one required in addition to the inlet and outlet erosion protection.",
                    "attrs": {
                        "row": 7,
                        "col": 0,
                        "rowspan": 1,
                        "colspan": 2
                    }
                },
                {
                    "id": "p198.1.9",
                    "order": 10,
                    "type": "table_cell",
                    "bbox": {
                        "l": 70.8,
                        "t": 349.8171,
                        "r": 594,
                        "b": 296.9143
                    },
                    "text": "3. Discharge shall be to a paved street, channel, or an approved drainage course with grouted riprap. Ripap shall be 12\" minimum size rock. Ripap shall be embedded in a minimum 6\" into grout.",
                    "attrs": {
                        "row": 8,
                        "col": 0,
                        "rowspan": 1,
                        "colspan": 2
                    }
                },
                {
                    "id": "p198.1.10",
                    "order": 11,
                    "type": "table_cell",
                    "bbox": {
                        "l": 70.8,
                        "t": 296.9143,
                        "r": 594,
                        "b": 244.0114
                    },
                    "text": "4. The drain pipe shall be a minimum of 15\" in diameter and shall be constructed with water tight joints.",
                    "attrs": {
                        "row": 9,
                        "col": 0,
                        "rowspan": 1,
                        "colspan": 2
                    }
                },
                {
                    "id": "p198.1.11",
                    "order": 12,
                    "type": "table_cell",
                    "bbox": {
                        "l": 70.8,
                        "t": 244.0114,
                        "r": 594,
                        "b": 191.1086
                    },
                    "text": "5. All concrete shall be Portland Cement Concrete 420-C-2000 unless otherwise specified.",
                    "attrs": {
                        "row": 10,
                        "col": 0,
                        "rowspan": 1,
                        "colspan": 2
                    }
                },
                {
                    "id": "p198.1.12",
                    "order": 13,
                    "type": "table_cell",
                    "bbox": {
                        "l": 70.8,
                        "t": 191.1086,
                        "r": 594,
                        "b": 138.2057
                    },
                    "text": "CITY OF PALMDALE...",
                    "attrs": {
                        "row": 11,
                        "col": 0,
                        "rowspan": 1,
                        "colspan": 2
                    }
                },
                {
                    "id": "p198.1.13",
                    "order": 14,
                    "type": "table_cell",
                    "bbox": {
                        "l": 70.8,
                        "t": 138.2057,
                        "r": 332.4,
                        "b": 85.3029
                    },
                    "text": "BASIN NOTES",
                    "attrs": {
                        "row": 12,
                        "col": 0,
                        "rowspan": 1,
                        "colspan": 1
                    }
                },
                {
                    "id": "p198.1.14",
                    "order": 15,
                    "type": "table_cell",
                    "bbox": {
                        "l": 332.4,
                        "t": 138.2057,
                        "r": 594,
                        "b": 85.3029
                    },
                    "text": "Std. No.",
                    "attrs": {
                        "row": 12,
                        "col": 1,
                        "rowspan": 1,
                        "colspan": 1
                    }
                },
                {
                    "id": "p198.1.15",
                    "order": 16,
                    "type": "table_cell",
                    "bbox": {
                        "l": 70.8,
                        "t": 85.3029,
                        "r": 332.4,
                        "b": 32.4
                    },
                    "text": "Approved City Engineer Date",
                    "attrs": {
                        "row": 13,
                        "col": 0,
                        "rowspan": 1,
                        "colspan": 1
                    }
                },
                {
                    "id": "p198.1.16",
                    "order": 17,
                    "type": "table_cell",
                    "bbox": {
                        "l": 332.4,
                        "t": 85.3029,
                        "r": 594,
                        "b": 32.4
                    },
                    "text": "D-7.2",
                    "attrs": {
                        "row": 13,
                        "col": 1,
                        "rowspan": 1,
                        "colspan": 1
                    }
                }
            ]
        }
    ],
    "excluded_furniture": {
        "first": [],
        "last": []
    }
}