            "id": "p131.1",
            "order": 1,
            "type": "list",
            "bbox": {
                "l": 63.12,
                "t": 715.2,
                "r": 558.24,
                "b": 345.12
            },
            "text": "",
            "attrs": {
                "item_count": 8
            },
            "children": [
                {
                    "id": "p131.1.1",
                    "order": 2,
                    "type": "list_item",
                    "bbox": {
                        "l": 102.72,
                        "t": 715.2,
                        "r": 558.24,
                        "b": 681.36
                    },
                    "text": "The controller chart shall be a blackline or blueline ozalid print. A different color shall be used to indicate the area of coverage for each station (valve).",
                    "marker": "e."
                },
                {
                    "id": "p131.1.2",
                    "order": 3,
                    "type": "list_item",
                    "bbox": {
                        "l": 102.96,
                        "t": 668.88,
                        "r": 558,
                        "b": 619.92
                    },
                    "text": "When completed and approved, the controller chart shall be hermetically sealed between two pieces of plastic, each piece being a minimum of 10 mils thick.",
                    "marker": "f."
                },
                {
                    "id": "p131.1.3",
                    "order": 4,
                    "type": "list_item",
                    "bbox": {
                        "l": 102.48,
                        "t": 605.04,
                        "r": 557.04,
                        "b": 571.92
                    },
                    "text": "These controller charts shall be completed and approved prior to final inspection of the irrigation system.",
                    "marker": "g."
                },
                {
                    "id": "p131.1.4",
                    "order": 5,
                    "type": "list_item",
                    "bbox": {
                        "l": 63.12,
                        "t": 542.64,
                        "r": 557.52,
                        "b": 492
                    },
                    "text": "The backflow prevention device shall be tested and certified by the Los Angeles County Department of Health Services - Cross Connections and Water Pollution Control Program and proof submitted to the City of Palmdale.",
                    "marker": "5."
                },
                {
                    "id": "p131.1.5",
                    "order": 6,
                    "type": "list_item",
                    "bbox": {
                        "l": 65.52,
                        "t": 479.76,
                        "r": 516.72,
                        "b": 460.8
                    },
                    "text": "The irrigation system shall be flushed prior to installation of irrigation heads.",
                    "marker": "6."
                },
                {
                    "id": "p131.1.6",
                    "order": 7,
                    "type": "list_item",
                    "bbox": {
                        "l": 66,
                        "t": 448.08,
                        "r": 556.08,
                        "b": 415.2
                    },
                    "text": "Final location of the automatic controller shall be approved by the City Landscape Architect.",
                    "marker": "7."
                },
                {
                    "id": "p131.1.7",
                    "order": 8,
                    "type": "list_item",
                    "bbox": {
                        "l": 65.76,
                        "t": 402,
                        "r": 547.44,
                        "b": 381.84
                    },
                    "text": "The irrigation trenches shall not be backfilled until all required tests are performed.",
                    "marker": "8."
                },
                {
                    "id": "p131.1.8",
                    "order": 9,
                    "type": "list_item",
                    "bbox": {
                        "l": 66,
                        "t": 361.92,
                        "r": 203.52,
                        "b": 345.12
                    },
                    "text": "Field Quality Control",
                    "marker": "9.",
                    "attrs": {
                        "block_label": "paragraph_title"
                    }
                }
            ]
        },
        {
            "id": "p131.2",
            "order": 10,
            "type": "text",
            "bbox": {
                "l": 85.68,
                "t": 337.44,
                "r": 227.04,
                "b": 320.16
            },
            "text": "Adjustment of the System"
        },
        {
            "id": "p131.3",
            "order": 11,
            "type": "list",
            "bbox": {
                "l": 101.28,
                "t": 305.04,
                "r": 556.08,
                "b": 130.8
            },
            "text": "",
            "attrs": {
                "item_count": 3
            },
            "children": [
                {
                    "id": "p131.3.1",
                    "order": 12,
                    "type": "list_item",
                    "bbox": {
                        "l": 101.28,
                        "t": 305.04,
                        "r": 555.84,
                        "b": 256.56
                    },
                    "text": "The Contractor shall flush and adjust all sprinkler heads for optimum performance and to prevent overspray onto walks, roadways, and buildings as much as possible.",
                    "marker": "a."
                },
                {
                    "id": "p131.3.2",
                    "order": 13,
                    "type": "list_item",
                    "bbox": {
                        "l": 101.28,
                        "t": 242.4,
                        "r": 556.08,
                        "b": 178.08
                    },
                    "text": "If it is determined that adjustments in the irrigation equipment will provide proper and more adequate coverage, the Contractor shall make such adjustments prior to planting. Adjustments may also include changes in sizes and degrees of arc as required.",
                    "marker": "b."
                },
                {
                    "id": "p131.3.3",
                    "order": 14,
                    "type": "list_item",
                    "bbox": {
                        "l": 101.52,
                        "t": 163.2,
                        "r": 555.36,
                        "b": 130.8
                    },
                    "text": "Lowering raised sprinkler heads by the Contractor shall be accomplished within 10 days after notification by the City.",
                    "marker": "c."
                }
            ]
        },
        {
            "id": "p131.4",
            "order": 15,
            "type": "text",
            "bbox": {
                "l": 289.92,
                "t": 83.52,
                "r": 331.68,
                "b": 68.88
            },
            "text": "VI - 12",
            "attrs": {
                "block_label": "number"
            }
        },
        {
            "id": "p131.5",
            "order": 16,
            "type": "footer",
            "bbox": {
                "l": 12.96,
                "t": 104.88,
                "r": 41.28,
                "b": 76.32
            },
            "text": "",
            "attrs": {
                "block_label": "footer_image"
            }
        }
    ],
    "excluded_furniture": {
        "first": [],
        "last": []
    }
}