{
    "document_id": 11428,
    "page": 127,
    "width_pt": 612,
    "height_pt": 792,
    "rotation": 0,
    "pipeline_version": "paddleocr-vl-1.6+paul-48",
    "engine": "paddleocr_vl",
    "source_run_id": 11539,
    "item_count": 17,
    "counts_by_type": {
        "footer": 1,
        "header": 1,
        "heading": 2,
        "text": 13
    },
    "build_ms": 1,
    "items": [
        {
            "id": "p127.1",
            "order": 1,
            "type": "header",
            "bbox": {
                "l": 238.56,
                "t": 792,
                "r": 336.48,
                "b": 786.72
            },
            "text": "",
            "attrs": {
                "block_label": "header"
            },
            "level": 2
        },
        {
            "id": "p127.2",
            "order": 2,
            "type": "text",
            "bbox": {
                "l": 67.68,
                "t": 698.88,
                "r": 361.68,
                "b": 682.08
            },
            "text": "All fittings shall be standard weight Schedule 40 PVC."
        },
        {
            "id": "p127.3",
            "order": 3,
            "type": "text",
            "bbox": {
                "l": 67.2,
                "t": 674.16,
                "r": 540.48,
                "b": 609.36
            },
            "text": "All threaded nipples shall be standard weight Schedule 80 with molded threads.\nSolvent cement joints shall be made as prescribed by the manufacturer. An aggressive primer shall be used in conjunction with a solvent primer designed for the fit of the pipe and fittings of each size range specified."
        },
        {
            "id": "p127.4",
            "order": 4,
            "type": "text",
            "bbox": {
                "l": 67.2,
                "t": 586.56,
                "r": 435.84,
                "b": 570
            },
            "text": "Provide a minimum of 24\" cover for all pressure lines 4\" and larger."
        },
        {
            "id": "p127.5",
            "order": 5,
            "type": "text",
            "bbox": {
                "l": 67.44,
                "t": 562.56,
                "r": 436.32,
                "b": 546
            },
            "text": "Provide a minimum of 18\" cover for all pressure lines 3\" or smaller."
        },
        {
            "id": "p127.6",
            "order": 6,
            "type": "text",
            "bbox": {
                "l": 67.2,
                "t": 538.32,
                "r": 387.12,
                "b": 521.76
            },
            "text": "Provide a minimum of 12\" cover for all non-pressure lines."
        },
        {
            "id": "p127.7",
            "order": 7,
            "type": "text",
            "bbox": {
                "l": 67.44,
                "t": 506.4,
                "r": 551.04,
                "b": 474.24
            },
            "text": "Concrete thrust blocks shall be installed on all pressure line changes of direction and pipes exceeding 2\" in diameter."
        },
        {
            "id": "p127.8",
            "order": 8,
            "type": "heading",
            "bbox": {
                "l": 67.68,
                "t": 459.6,
                "r": 172.08,
                "b": 443.28
            },
            "text": "d. Sprinkler Heads",
            "attrs": {
                "block_label": "paragraph_title"
            },
            "level": 3
        },
        {
            "id": "p127.9",
            "order": 9,
            "type": "text",
            "bbox": {
                "l": 67.2,
                "t": 428.16,
                "r": 410.4,
                "b": 411.6
            },
            "text": "Double ell swing joints shall be installed on all riser assemblies."
        },
        {
            "id": "p127.10",
            "order": 10,
            "type": "text",
            "bbox": {
                "l": 67.68,
                "t": 396.96,
                "r": 381.6,
                "b": 379.44
            },
            "text": "All spray heads in the right-of-way shall be a pop-up type."
        },
        {
            "id": "p127.11",
            "order": 11,
            "type": "text",
            "bbox": {
                "l": 67.68,
                "t": 365.76,
                "r": 300.24,
                "b": 348.72
            },
            "text": "Spray heads shall have a screw adjustment."
        },
        {
            "id": "p127.12",
            "order": 12,
            "type": "text",
            "bbox": {
                "l": 67.92,
                "t": 334.32,
                "r": 521.52,
                "b": 301.92
            },
            "text": "Riser nipples for all sprinkler heads shall be the same size as the riser opening of the sprinkler body."
        },
        {
            "id": "p127.13",
            "order": 13,
            "type": "heading",
            "bbox": {
                "l": 68.4,
                "t": 287.28,
                "r": 133.44,
                "b": 271.2
            },
            "text": "e. Bubblers",
            "attrs": {
                "block_label": "paragraph_title"
            },
            "level": 3
        },
        {
            "id": "p127.14",
            "order": 14,
            "type": "text",
            "bbox": {
                "l": 68.16,
                "t": 255.84,
                "r": 531.6,
                "b": 205.92
            },
            "text": "A tree bubbler system shall be installed to each tree (see detail). A bubbler shall be installed to each shrub unless the planter shall be irrigated with flat spray heads on 12\" high pop sprinters. All bubblers shall be pressure compensating."
        },
        {
            "id": "p127.15",
            "order": 15,
            "type": "text",
            "bbox": {
                "l": 68.64,
                "t": 192.72,
                "r": 482.64,
                "b": 174.48
            },
            "text": "All tree bubblers shall be installed on valves separate from the other planting."
        },
        {
            "id": "p127.16",
            "order": 16,
            "type": "text",
            "bbox": {
                "l": 295.2,
                "t": 80.88,
                "r": 331.44,
                "b": 65.76
            },
            "text": "VI-8",
            "attrs": {
                "block_label": "number"
            }
        },
        {
            "id": "p127.17",
            "order": 17,
            "type": "footer",
            "bbox": {
                "l": 12.96,
                "t": 103.2,
                "r": 41.28,
                "b": 75.6
            },
            "text": "",
            "attrs": {
                "block_label": "footer_image"
            }
        }
    ],
    "excluded_furniture": {
        "first": [],
        "last": []
    }
}