            "id": "p7.1",
            "order": 1,
            "type": "header",
            "bbox": {
                "l": 69.12,
                "t": 755.52,
                "r": 226.32,
                "b": 729.6
            },
            "text": "Jackson Township Planning Board\nOur file No. 1512-P-635",
            "attrs": {
                "block_label": "header"
            },
            "level": 2
        },
        {
            "id": "p7.2",
            "order": 2,
            "type": "header",
            "bbox": {
                "l": 69.84,
                "t": 723.12,
                "r": 103.92,
                "b": 710.64
            },
            "text": "Page 7",
            "attrs": {
                "block_label": "number"
            },
            "level": 2
        },
        {
            "id": "p7.3",
            "order": 3,
            "type": "text",
            "bbox": {
                "l": 122.16,
                "t": 683.52,
                "r": 559.44,
                "b": 644.64
            },
            "text": "PVC, RGC and HC Zones. Testimony shall be provided to discuss the Applicant's intention to propose an identification sign. If signage is proposed details shall be provided and the location shown on the plan."
        },
        {
            "id": "p7.4",
            "order": 4,
            "type": "text",
            "bbox": {
                "l": 104.16,
                "t": 641.76,
                "r": 559.68,
                "b": 602.88
            },
            "text": "2. Per §244-207B(7) each principal building may have one wall sign not to exceed 15% of the principal façade area or 80 sf, whichever is smaller. The architectural elevations depict a wall sign on the left elevation on sheet A5. A detail shall be provided to determine compliance."
        },
        {
            "id": "p7.5",
            "order": 5,
            "type": "heading",
            "bbox": {
                "l": 87.36,
                "t": 599.52,
                "r": 294.72,
                "b": 586.32
            },
            "text": "D. Traffic, Circulation, Parking and Loading",
            "attrs": {
                "block_label": "paragraph_title"
            },
            "level": 3
        },
        {
            "id": "p7.6",
            "order": 6,
            "type": "list",
            "bbox": {
                "l": 104.16,
                "t": 582.96,
                "r": 561.12,
                "b": 72
            },
            "text": "",
            "attrs": {
                "item_count": 11
            },
            "children": [
                {
                    "id": "p7.6.1",
                    "order": 7,
                    "type": "list_item",
                    "bbox": {
                        "l": 105.12,
                        "t": 582.96,
                        "r": 559.44,
                        "b": 556.8
                    },
                    "text": "The Applicant shall provide testimony to discuss any proposed roadway improvements within the South New Prospect Road right-of-way and the timing of the improvements.",
                    "marker": "1."
                },
                {
                    "id": "p7.6.2",
                    "order": 8,
                    "type": "list_item",
                    "bbox": {
                        "l": 104.4,
                        "t": 553.68,
                        "r": 559.92,
                        "b": 515.04
                    },
                    "text": "The Applicant shall provide testimony to discuss the potential traffic impacts as a result of the proposed development. We note the traffic impact analysis is dated July 2025 and the traffic counts within the analysis are dated February 2024.",
                    "marker": "2."
                },
                {
                    "id": "p7.6.3",
                    "order": 9,
                    "type": "list_item",
                    "bbox": {
                        "l": 104.4,
                        "t": 511.68,
                        "r": 559.68,
                        "b": 473.52
                    },
                    "text": "The Applicant is proposing access to the site by way of a one-way entrance drive and a one-way exit drive along South New Prospect Road. Testimony shall be provided to discuss vehicular circulation in and out of the site.",
                    "marker": "3."
                },
                {
                    "id": "p7.6.4",
                    "order": 10,
                    "type": "list_item",
                    "bbox": {
                        "l": 104.4,
                        "t": 470.16,
                        "r": 560.16,
                        "b": 430.8
                    },
                    "text": "The Applicant shall provide testimony to discuss vehicular circulation within the dead-end parking areas. The northerly parking area provides a small turnaround area. The southerly parking area with the accessible parking stalls provides no turnaround area.",
                    "marker": "4."
                },
                {
                    "id": "p7.6.5",
                    "order": 11,
                    "type": "list_item",
                    "bbox": {
                        "l": 104.88,
                        "t": 427.92,
                        "r": 559.68,
                        "b": 402.24
                    },
                    "text": "The circulation plan for the fire truck has been revised. Testimony shall be provided to discuss the fire truck circulation.",
                    "marker": "5."
                },
                {
                    "id": "p7.6.6",
                    "order": 12,
                    "type": "list_item",
                    "bbox": {
                        "l": 104.64,
                        "t": 398.64,
                        "r": 560.4,
                        "b": 359.76
                    },
                    "text": "The circulation plan for the refuse truck appears to depict the refuse truck entering the site through the exit drive and leaving the site through the entrance drive. The plan shall be revised accordingly to ensure the circulation for the trash truck is adequate.",
                    "marker": "6."
                },
                {
                    "id": "p7.6.7",
                    "order": 13,
                    "type": "list_item",
                    "bbox": {
                        "l": 104.16,
                        "t": 356.4,
                        "r": 561.12,
                        "b": 229.2
                    },
                    "text": "Per §244-196A for every building, structure or part thereof having over 10,000 square feet of gross floor area erected and occupied for any use other than residential, there shall be provided at least one truck standing, loading and unloading space on the premises, not less than 12 feet in width, 35 feet in length and with a minimum vertical clearance of 14 feet. Buildings that contain an excess of 15,000 square feet of gross floor area shall be required to provide additional off-street loading spaces as determined by the municipal agency during site plan review, whereas the Applicant proposes a 22,148 sf building and no loading and unloading space is proposed. The Applicant shall provide testimony to discuss the need for a loading and unloading space. The Applicant shall discuss the size truck anticipate for deliveries and where the truck will be stopped during deliveries.",
                    "marker": "7."
                },
                {
                    "id": "p7.6.8",
                    "order": 14,
                    "type": "list_item",
                    "bbox": {
                        "l": 105.12,
                        "t": 226.08,
                        "r": 560.16,
                        "b": 174.72
                    },
                    "text": "Per §244-197J(2)(a)[2][a] all entrance drives shall extend a minimum distance of 100 feet back from the street right-of-way or to a parking access aisle or major circulation drive, whereas approximately 50 ft is provided. The plans should be revised, or the Applicant shall request a waiver.",
                    "marker": "8."
                },
                {
                    "id": "p7.6.9",
                    "order": 15,
                    "type": "list_item",
                    "bbox": {
                        "l": 104.64,
                        "t": 171.6,
                        "r": 560.16,
                        "b": 132.72
                    },
                    "text": "Per §244-197J(2)(a)[2][b] all exit drives shall extend a minimum distance of 60 feet back from the street curb or to a parking access aisle or major circulation drive, whereas approximately 50 ft is provided. The plans should be revised, or the Applicant shall request a waiver.",
                    "marker": "9."
                },
                {
                    "id": "p7.6.10",
                    "order": 16,
                    "type": "list_item",
                    "bbox": {
                        "l": 106.56,
                        "t": 129.84,
                        "r": 560.64,
                        "b": 90.48
                    },
                    "text": "Per §244-197J(2)(a)[2][c] no parking stalls shall utilize the required entrance and exit drives or major circulation drives as parking access aisles, whereas the parking accesses the main circulation drive. The plans should be revised, or the Applicant shall request a waiver.",
                    "marker": "10."
                },
                {
                    "id": "p7.6.11",
                    "order": 17,
                    "type": "list_item",
                    "bbox": {
                        "l": 105.12,
                        "t": 85.44,
                        "r": 465.84,
                        "b": 72
                    },
                    "text": "Testimony shall be provided to discuss pedestrian and accessible circulation.",
                    "marker": "11."
                }
            ]
        },
        {