{
    "document_id": 10904,
    "page": 2,
    "width_pt": 612,
    "height_pt": 792,
    "rotation": 0,
    "pipeline_version": "paddleocr-vl-1.6+paul-48",
    "engine": "paddleocr_vl",
    "source_run_id": 11013,
    "item_count": 12,
    "counts_by_type": {
        "heading": 2,
        "list": 1,
        "list_item": 7,
        "text": 2
    },
    "build_ms": 1,
    "items": [
        {
            "id": "p2.1",
            "order": 1,
            "type": "heading",
            "bbox": {
                "l": 256.32,
                "t": 711.6,
                "r": 355.2,
                "b": 699.36
            },
            "text": "Sampling Procedures",
            "attrs": {
                "block_label": "paragraph_title"
            },
            "level": 3
        },
        {
            "id": "p2.2",
            "order": 2,
            "type": "text",
            "bbox": {
                "l": 105.36,
                "t": 684.72,
                "r": 537.84,
                "b": 644.88
            },
            "text": "When weather and environmental conditions permit, manhole openings and covers of milk tank trucks may be opened outdoors for the short period of time necessary for the collection of samples for animal drug residue screening. Follow company protocol."
        },
        {
            "id": "p2.3",
            "order": 3,
            "type": "list",
            "bbox": {
                "l": 86.88,
                "t": 631.2,
                "r": 535.92,
                "b": 403.68
            },
            "text": "",
            "attrs": {
                "item_count": 7
            },
            "children": [
                {
                    "id": "p2.3.1",
                    "order": 4,
                    "type": "list_item",
                    "bbox": {
                        "l": 87.6,
                        "t": 631.2,
                        "r": 534.96,
                        "b": 579.12
                    },
                    "text": "Protect sampling instruments from exposure to contamination before and during use. Handle sample containers and caps aseptically maintaining sterility. Do not drop, lay down or touch the inside of or otherwise contaminate sterile containers. Do not carry sample containers in your pocket.",
                    "marker": "1."
                },
                {
                    "id": "p2.3.2",
                    "order": 5,
                    "type": "list_item",
                    "bbox": {
                        "l": 88.32,
                        "t": 576.96,
                        "r": 201.6,
                        "b": 565.44
                    },
                    "text": "Wash and dry hands.",
                    "marker": "2."
                },
                {
                    "id": "p2.3.3",
                    "order": 6,
                    "type": "list_item",
                    "bbox": {
                        "l": 88.08,
                        "t": 563.52,
                        "r": 263.76,
                        "b": 552
                    },
                    "text": "Check the temperature of the milk.",
                    "marker": "3."
                },
                {
                    "id": "p2.3.4",
                    "order": 7,
                    "type": "list_item",
                    "bbox": {
                        "l": 87.36,
                        "t": 550.32,
                        "r": 535.92,
                        "b": 498
                    },
                    "text": "A second sample is required for a temperature control (TC). Temperature control samples are to be collected at each sampling point for raw milk in dairy plants and each over-the-road tanker. Temperature control samples must be labeled with the time, date, temperature at time of collection and the name or initials of the person collecting the sample.",
                    "marker": "4."
                },
                {
                    "id": "p2.3.5",
                    "order": 8,
                    "type": "list_item",
                    "bbox": {
                        "l": 86.88,
                        "t": 496.56,
                        "r": 532.8,
                        "b": 430.8
                    },
                    "text": "Collect tanker samples. Open manhole lid, rinse sample dipper in the milk twice to remove any traces of sanitizer. Dipper should extend 6 to 8 inches into milk to obtain a representative sample. Insert dipper into milk and then hold the sample container away from the manhole, fill the container about 3/4 full. Close the lid of the sample container taking care not to touch the inside of the lid. Identify sample with date, time, temperature, and sampler ID.",
                    "marker": "5."
                },
                {
                    "id": "p2.3.6",
                    "order": 9,
                    "type": "list_item",
                    "bbox": {
                        "l": 88.08,
                        "t": 429.12,
                        "r": 506.16,
                        "b": 417.12
                    },
                    "text": "Rinse the sample dipper with cool water and replace in the sanitizing solution for storage.",
                    "marker": "6."
                },
                {
                    "id": "p2.3.7",
                    "order": 10,
                    "type": "list_item",
                    "bbox": {
                        "l": 88.32,
                        "t": 415.44,
                        "r": 397.92,
                        "b": 403.68
                    },
                    "text": "Follow company's policy on testing the sample for drug residues.",
                    "marker": "7."
                }
            ]
        },
        {
            "id": "p2.4",
            "order": 11,
            "type": "heading",
            "bbox": {
                "l": 295.68,
                "t": 390.48,
                "r": 353.52,
                "b": 378.48
            },
            "text": "LICENSING",
            "attrs": {
                "block_label": "paragraph_title"
            },
            "level": 3
        },
        {
            "id": "p2.5",
            "order": 12,
            "type": "text",
            "bbox": {
                "l": 105.36,
                "t": 364.56,
                "r": 545.28,
                "b": 324.48
            },
            "text": "Upon satisfactory completion of an industry training program and the milk inspector's evaluation, all prospective haulers must complete an application for a Plant Sampler License. Upon receipt of the application and required fees, the Department of Livestock will issue the license."
        }
    ],
    "excluded_furniture": {
        "first": [],
        "last": []
    }
}