{
    "document_id": 10404,
    "page": 52,
    "width_pt": 612,
    "height_pt": 792,
    "rotation": 0,
    "pipeline_version": "paddleocr-vl-1.6+paul-48",
    "engine": "paddleocr_vl",
    "source_run_id": 10515,
    "item_count": 15,
    "counts_by_type": {
        "figure": 1,
        "footer": 1,
        "header": 1,
        "heading": 1,
        "list": 1,
        "list_item": 7,
        "text": 3
    },
    "build_ms": 1,
    "items": [
        {
            "id": "p52.1",
            "order": 1,
            "type": "header",
            "bbox": {
                "l": 77.5471,
                "t": 733.0493,
                "r": 378.6406,
                "b": 687.7579
            },
            "text": "Sarasota Manatee Airport\nConsolidated Rental Car Facility, Quick Turnaround, and Maintenance\nProfessional Engineering Services Proposal\nPage 16",
            "attrs": {
                "block_label": "header"
            },
            "level": 2
        },
        {
            "id": "p52.2",
            "order": 2,
            "type": "figure",
            "bbox": {
                "l": 485.3876,
                "t": 730.4133,
                "r": 534.4529,
                "b": 712.6802
            },
            "text": "",
            "attrs": {
                "role": "page_header",
                "block_label": "header_image",
                "embedded_text": "JilTLC"
            }
        },
        {
            "id": "p52.3",
            "order": 3,
            "type": "heading",
            "bbox": {
                "l": 77.3078,
                "t": 677.2139,
                "r": 321.4376,
                "b": 665.2321
            },
            "text": "Fire Protection Note: fire protection not anticipated",
            "attrs": {
                "block_label": "paragraph_title"
            },
            "level": 3
        },
        {
            "id": "p52.4",
            "order": 4,
            "type": "list",
            "bbox": {
                "l": 107.2257,
                "t": 664.9924,
                "r": 524.6398,
                "b": 407.6224
            },
            "text": "",
            "attrs": {
                "item_count": 7
            },
            "children": [
                {
                    "id": "p52.4.1",
                    "order": 5,
                    "type": "list_item",
                    "bbox": {
                        "l": 108.183,
                        "t": 664.9924,
                        "r": 506.2104,
                        "b": 627.1298
                    },
                    "text": "Fire Protection Service: A service line will be connected at the street water main. The service will be routed directly across the street to an above grade double detection backflow preventer, then routed underground into the building.",
                    "marker": "1."
                },
                {
                    "id": "p52.4.2",
                    "order": 6,
                    "type": "list_item",
                    "bbox": {
                        "l": 107.2257,
                        "t": 617.0651,
                        "r": 514.1087,
                        "b": 590.9446
                    },
                    "text": "Flow Test: a flow test will be conducted to determine that the city water pressure is sufficient, and not required a fire pump.",
                    "marker": "2."
                },
                {
                    "id": "p52.4.3",
                    "order": 7,
                    "type": "list_item",
                    "bbox": {
                        "l": 107.7043,
                        "t": 580.4006,
                        "r": 522.007,
                        "b": 517.3761
                    },
                    "text": "Fire service location: A mechanical space with 5'x5' room is required for the service riser. Optimally this room would be located on an exterior wall that faces the service street for an exterior door, and a location for a wall mounted fire department connection. Additionally, zone control valves servicing the wet sprinkler system system should be co-located here.",
                    "marker": "3."
                },
                {
                    "id": "p52.4.4",
                    "order": 8,
                    "type": "list_item",
                    "bbox": {
                        "l": 107.2257,
                        "t": 507.0717,
                        "r": 205.3563,
                        "b": 492.9331
                    },
                    "text": "Sprinkler Piping:",
                    "marker": "4.",
                    "attrs": {
                        "block_label": "paragraph_title"
                    }
                },
                {
                    "id": "p52.4.5",
                    "order": 9,
                    "type": "list_item",
                    "bbox": {
                        "l": 128.5272,
                        "t": 481.1909,
                        "r": 524.6398,
                        "b": 445.0057
                    },
                    "text": "Wet System: Provide seamless black steel piping with malleable fittings above grade. Schedule 40 threaded - 1\" and smaller. Schedule 40 roll grooved - 2-1/2\" and larger.",
                    "marker": "a."
                },
                {
                    "id": "p52.4.6",
                    "order": 10,
                    "type": "list_item",
                    "bbox": {
                        "l": 128.2878,
                        "t": 444.5265,
                        "r": 489.2171,
                        "b": 430.8672
                    },
                    "text": "Pre-Action: galvanized Schedule 40 piping for drainage of piping system.",
                    "marker": "b."
                },
                {
                    "id": "p52.4.7",
                    "order": 11,
                    "type": "list_item",
                    "bbox": {
                        "l": 107.2257,
                        "t": 421.0421,
                        "r": 474.6171,
                        "b": 407.6224
                    },
                    "text": "Sprinklers (Office Areas): The rental car offices and back of house spaces.",
                    "marker": "5."
                }
            ]
        },
        {
            "id": "p52.5",
            "order": 12,
            "type": "text",
            "bbox": {
                "l": 130.9206,
                "t": 420.0835,
                "r": 404.011,
                "b": 333.5746
            },
            "text": "Sprinklers (Office Areas): The rental car offices and back of a. Sprinkler system design criteria for this area shall be: Occupancy Classification Light Hazard Density 0.1 GPM/Sq.Ft. Hydraulic Remote Area 1500 Sq.Ft. Maximum Coverage per Sprinkler 400 sq.ft. Sprinkler Type (all ceilings) Concealed"
        },
        {
            "id": "p52.6",
            "order": 13,
            "type": "text",
            "bbox": {
                "l": 107.2257,
                "t": 323.2702,
                "r": 371.6996,
                "b": 310.5694
            },
            "text": "6. Sprinklers (Mechanical Areas and Storage Rooms):"
        },
        {
            "id": "p52.7",
            "order": 14,
            "type": "text",
            "bbox": {
                "l": 128.7665,
                "t": 309.3713,
                "r": 444.9386,
                "b": 234.8442
            },
            "text": "a. Sprinkler system design criteria for this area shall be:\nOccupancy Classification\nDensity\nHydraulic Remote Area\nMaximum Coverage per Sprinkler\nSprinkler Type\nOrdinary Hazard, Group 2\n0.2 GPM/Sq.Ft.\n1500 Sq.Ft.\n225 sq.ft.\nUpright or Pendent"
        },
        {
            "id": "p52.8",
            "order": 15,
            "type": "footer",
            "bbox": {
                "l": 207.989,
                "t": 51.7616,
                "r": 395.3946,
                "b": 33.5492
            },
            "text": "THINK. LISTEN. CREATE.",
            "attrs": {
                "block_label": "footer"
            }
        }
    ],
    "excluded_furniture": {
        "first": [],
        "last": []
    }
}