    "document_id": 10404,
    "page": 51,
    "width_pt": 612,
    "height_pt": 792,
    "rotation": 0,
    "pipeline_version": "paddleocr-vl-1.6+paul-48",
    "engine": "paddleocr_vl",
    "source_run_id": 10515,
    "item_count": 15,
    "counts_by_type": {
        "figure": 1,
        "footer": 1,
        "header": 1,
        "list": 1,
        "list_item": 11
    },
    "build_ms": 2,
    "items": [
        {
            "id": "p51.1",
            "order": 1,
            "type": "header",
            "bbox": {
                "l": 76.8,
                "t": 733.92,
                "r": 378.96,
                "b": 690.24
            },
            "text": "Sarasota Manatee Airport\nConsolidated Rental Car Facility, Quick Turnaround, and Maintenance\nProfessional Engineering Services Proposal\nPage 15",
            "attrs": {
                "block_label": "header"
            },
            "level": 2
        },
        {
            "id": "p51.2",
            "order": 2,
            "type": "figure",
            "bbox": {
                "l": 486,
                "t": 731.04,
                "r": 535.2,
                "b": 713.52
            },
            "text": "",
            "attrs": {
                "role": "page_header",
                "block_label": "header_image",
                "embedded_text": "..lTLC"
            }
        },
        {
            "id": "p51.3",
            "order": 3,
            "type": "list",
            "bbox": {
                "l": 106.8,
                "t": 678,
                "r": 530.4,
                "b": 151.68
            },
            "text": "",
            "attrs": {
                "item_count": 11
            },
            "children": [
                {
                    "id": "p51.3.1",
                    "order": 4,
                    "type": "list_item",
                    "bbox": {
                        "l": 128.88,
                        "t": 678,
                        "r": 262.08,
                        "b": 665.28
                    },
                    "text": "Compressed air system",
                    "marker": "f."
                },
                {
                    "id": "p51.3.2",
                    "order": 5,
                    "type": "list_item",
                    "bbox": {
                        "l": 129.6,
                        "t": 665.28,
                        "r": 242.4,
                        "b": 653.04
                    },
                    "text": "Cleaning / Vacuum.",
                    "marker": "g."
                },
                {
                    "id": "p51.3.3",
                    "order": 6,
                    "type": "list_item",
                    "bbox": {
                        "l": 129.6,
                        "t": 652.8,
                        "r": 296.4,
                        "b": 640.08
                    },
                    "text": "Carwash reclaim water system.",
                    "marker": "h."
                },
                {
                    "id": "p51.3.4",
                    "order": 7,
                    "type": "list_item",
                    "bbox": {
                        "l": 107.28,
                        "t": 617.04,
                        "r": 528,
                        "b": 542.16
                    },
                    "text": "Sanitary and Vent System: The facility will be provided with sanitary waste service for the drainage of male and female toilet rooms, sinks, showers, floor drains and floor sinks drainage, HVAC purpose, carwash bays and equipment drainage, maintenance bays drainage, fuel piping transition sump room drainage and compressed air system condensate drainage at each level as required. The waste drainage is expected to be a 6\" inch pipe at each level.",
                    "marker": "2."
                },
                {
                    "id": "p51.3.5",
                    "order": 8,
                    "type": "list_item",
                    "bbox": {
                        "l": 107.28,
                        "t": 531.84,
                        "r": 530.4,
                        "b": 456.24
                    },
                    "text": "Domestic Water System: The facility will be provided with domestic water for male and female toilet, sinks, showers, domestic water heating, HVAC, hose bibbs for facility's maintenance and cleaning purposes as required, carwash system fresh water makeup, maintenance bays usage, fueling island perimeter usage at each level, hose bibb at fuel piping transition sump room and compressed air system water supply. The domestic water supply line is expected to be 3\" at each level.",
                    "marker": "3."
                },
                {
                    "id": "p51.3.6",
                    "order": 9,
                    "type": "list_item",
                    "bbox": {
                        "l": 106.8,
                        "t": 445.68,
                        "r": 517.2,
                        "b": 408
                    },
                    "text": "Condensate Drainage system: The facility will be provided with a condensate drainage system at each level for HVAC purposes, with tie-in into the storm system within the building as required and in compliance with local codes.",
                    "marker": "4."
                },
                {
                    "id": "p51.3.7",
                    "order": 10,
                    "type": "list_item",
                    "bbox": {
                        "l": 107.04,
                        "t": 397.44,
                        "r": 527.28,
                        "b": 359.28
                    },
                    "text": "Storm Drainage System: The facility will be provided with the storm system for the drainage of the parking spaces at each level as required, with tie-ins with drop downs within the space in coordination with architect.",
                    "marker": "5."
                },
                {
                    "id": "p51.3.8",
                    "order": 11,
                    "type": "list_item",
                    "bbox": {
                        "l": 106.8,
                        "t": 348.48,
                        "r": 500.64,
                        "b": 322.32
                    },
                    "text": "Fueling System: The fueling system, piping and equipment (by others). Refer to sanitary and domestic water systems for requirements.",
                    "marker": "6."
                },
                {
                    "id": "p51.3.9",
                    "order": 12,
                    "type": "list_item",
                    "bbox": {
                        "l": 107.28,
                        "t": 312,
                        "r": 503.04,
                        "b": 286.32
                    },
                    "text": "Compressed Air System: The compressed air system, piping and equipment (by others). Refer to sanitary and domestic water systems for requirements.",
                    "marker": "7."
                },
                {
                    "id": "p51.3.10",
                    "order": 13,
                    "type": "list_item",
                    "bbox": {
                        "l": 107.28,
                        "t": 275.28,
                        "r": 519.12,
                        "b": 249.6
                    },
                    "text": "Cleaning / Vacuum System: The vacuum system, piping and equipment (by others). Refer to sanitary and domestic water systems for requirements.",
                    "marker": "8."
                },
                {
                    "id": "p51.3.11",
                    "order": 14,
                    "type": "list_item",
                    "bbox": {
                        "l": 107.28,
                        "t": 238.8,
                        "r": 529.2,
                        "b": 151.68
                    },
                    "text": "Carwash Reclaim Water System: The carwash will be a pre-engineered, automated system. Coordinated by plumbing system and carwash system contractors. The discharge water from each wash bay will be reclaimed and stored in underground oil water separator (aprox. 10,000 gal capacity), each oil separator will act as both: treatment and storage. Each floor will drain to its respective oil water separator, pump it up to three common holding tanks (aprox. 2,000 gal cap ea. By others). Refer to Sanitary and Domestic Water systems for requirements.",
                    "marker": "9."
                }
            ]
        },
        {
            "id": "p51.4",
            "order": 15,
            "type": "footer",
            "bbox": {
                "l": 209.28,
                "t": 50.4,
                "r": 396.72,
                "b": 33.6
            },
            "text": "THINK. LISTEN. CREATE.",
            "attrs": {
                "block_label": "footer"
            }
        }
    ],
    "excluded_furniture": {
        "first": [],
        "last": []
    }
}