    "document_id": 10400,
    "page": 50,
    "width_pt": 612,
    "height_pt": 792,
    "rotation": 0,
    "pipeline_version": "paddleocr-vl-1.6+paul-48",
    "engine": "paddleocr_vl",
    "source_run_id": 10511,
    "item_count": 19,
    "counts_by_type": {
        "figure": 1,
        "footer": 2,
        "header": 1,
        "heading": 1,
        "list": 1,
        "list_item": 7,
        "text": 6
    },
    "build_ms": 2,
    "items": [
        {
            "id": "p50.1",
            "order": 1,
            "type": "header",
            "bbox": {
                "l": 78,
                "t": 750,
                "r": 288.48,
                "b": 716.64
            },
            "text": "SRQ GENERAL AVIATION FIS FACILITY\nSARASOTA MANATEE AIRPORT AUTHORITY",
            "attrs": {
                "block_label": "header"
            },
            "level": 2
        },
        {
            "id": "p50.2",
            "order": 2,
            "type": "figure",
            "bbox": {
                "l": 466.8,
                "t": 757.44,
                "r": 532.56,
                "b": 718.32
            },
            "text": "",
            "attrs": {
                "role": "page_header",
                "block_label": "header_image",
                "embedded_text": "COMPANIES\""
            }
        },
        {
            "id": "p50.3",
            "order": 3,
            "type": "heading",
            "bbox": {
                "l": 78.24,
                "t": 674.16,
                "r": 220.32,
                "b": 659.28
            },
            "text": "D. BIM APPROACH",
            "attrs": {
                "block_label": "paragraph_title"
            },
            "level": 3
        },
        {
            "id": "p50.4",
            "order": 4,
            "type": "text",
            "bbox": {
                "l": 77.28,
                "t": 645.6,
                "r": 539.52,
                "b": 568.08
            },
            "text": "With all design disciplines in-house, C&S will use Revit (our 3D design platform) for the facility to develop various building systems in concert with one another to produce a coordinated set of construction documents. AutoDesk Civil3D will be used for flatwork to develop surfaces for grading, utility locations, stormwater routing, etc. in coordination with the airport and facility requirements."
        },
        {
            "id": "p50.5",
            "order": 5,
            "type": "text",
            "bbox": {
                "l": 77.52,
                "t": 557.04,
                "r": 538.8,
                "b": 494.64
            },
            "text": "The Design-Build team will setup a kickoff meeting with the SMAA BIM Manager to align expectations prior to beginning the modeling process. It is understood that C&S will be provided the SMAA BIM standards (If available) prior to commencement of the modeling process (assumed during initial meeting with the SMAA BIM Manager)."
        },
        {
            "id": "p50.6",
            "order": 6,
            "type": "text",
            "bbox": {
                "l": 77.52,
                "t": 484.08,
                "r": 538.56,
                "b": 454.32
            },
            "text": "Our standard BIM practice is to provide a 300 Level of Development (LOD), defined as follows:"
        },
        {
            "id": "p50.7",
            "order": 7,
            "type": "list",
            "bbox": {
                "l": 95.04,
                "t": 441.84,
                "r": 538.08,
                "b": 299.76
            },
            "text": "",
            "attrs": {
                "item_count": 4
            },
            "children": [
                {
                    "id": "p50.7.1",
                    "order": 8,
                    "type": "list_item",
                    "bbox": {
                        "l": 95.28,
                        "t": 441.84,
                        "r": 538.08,
                        "b": 411.36
                    },
                    "text": "Spatially accurate Architectural and building elements depicting a LOD 300 for all building and façade elements",
                    "marker": "-"
                },
                {
                    "id": "p50.7.2",
                    "order": 9,
                    "type": "list_item",
                    "bbox": {
                        "l": 95.28,
                        "t": 398.88,
                        "r": 537.6,
                        "b": 369.36
                    },
                    "text": "Spatially accurate MEP elements (i.e. size and maintenance clearances commensurate with equipment selection)",
                    "marker": "-"
                },
                {
                    "id": "p50.7.3",
                    "order": 10,
                    "type": "list_item",
                    "bbox": {
                        "l": 95.28,
                        "t": 357.36,
                        "r": 538.08,
                        "b": 326.4
                    },
                    "text": "Manufacturer info and capacities incorporated into families/schedules (provided only on new installation of equipment)"
                },
                {
                    "id": "p50.7.4",
                    "order": 11,
                    "type": "list_item",
                    "bbox": {
                        "l": 95.04,
                        "t": 314.88,
                        "r": 519.6,
                        "b": 299.76
                    },
                    "text": "Structural members depicted at correct size/type (i.e. joist, beams, trusses, etc.).",
                    "marker": "-"
                }
            ]
        },
        {
            "id": "p50.8",
            "order": 12,
            "type": "text",
            "bbox": {
                "l": 130.08,
                "t": 288,
                "r": 511.68,
                "b": 273.12
            },
            "text": "o Reinforcement and ancillary steel supports provided as 2D detail items"
        },
        {
            "id": "p50.9",
            "order": 13,
            "type": "list_item",
            "bbox": {
                "l": 94.8,
                "t": 260.88,
                "r": 400.32,
                "b": 246.48
            },
            "text": "Accurate duct sizing/routing coordinated with structure",
            "marker": "•"
        },
        {
            "id": "p50.10",
            "order": 14,
            "type": "text",
            "bbox": {
                "l": 129.84,
                "t": 234,
                "r": 537.84,
                "b": 204.48
            },
            "text": "o Limited to duct fittings/types provided in Revit template. Does not include custom-fabricated sheet steel objects."
        },
        {
            "id": "p50.11",
            "order": 15,
            "type": "list_item",
            "bbox": {
                "l": 95.28,
                "t": 192,
                "r": 537.84,
                "b": 161.76
            },
            "text": "Sloped piping and routing coordinated with structure (limited to pipe sizes 2-inch and larger)",
            "marker": "-"
        },
        {
            "id": "p50.12",
            "order": 16,
            "type": "text",
            "bbox": {
                "l": 77.28,
                "t": 149.76,
                "r": 537.84,
                "b": 120
            },
            "text": "We suggest splitting Revit models up amongst key design disciplines (coordinated with HCAA standards at kickoff):"
        },
        {
            "id": "p50.13",
            "order": 17,
            "type": "list_item",
            "bbox": {
                "l": 95.04,
                "t": 107.28,
                "r": 182.64,
                "b": 93.84
            },
            "text": "Architectural",
            "marker": "•"
        },
        {
            "id": "p50.14",
            "order": 18,
            "type": "footer",
            "bbox": {
                "l": 479.28,
                "t": 66.96,
                "r": 533.28,
                "b": 54.72
            },
            "text": "Page 38 of 93",
            "attrs": {
                "block_label": "number"
            }
        },
        {
            "id": "p50.15",
            "order": 19,
            "type": "footer",
            "bbox": {
                "l": 78.24,
                "t": 67.44,
                "r": 138,
                "b": 54.96
            },
            "text": "August 2, 2021",
            "attrs": {
                "block_label": "footer"
            }
        }
    ],
    "excluded_furniture": {
        "first": [],
        "last": []
    }
}