{
    "document_id": 10400,
    "page": 38,
    "width_pt": 612,
    "height_pt": 792,
    "rotation": 0,
    "pipeline_version": "paddleocr-vl-1.6+paul-48",
    "engine": "paddleocr_vl",
    "source_run_id": 10511,
    "item_count": 25,
    "counts_by_type": {
        "figure": 1,
        "footer": 2,
        "header": 1,
        "heading": 3,
        "list": 2,
        "list_item": 15,
        "text": 1
    },
    "build_ms": 2,
    "items": [
        {
            "id": "p38.1",
            "order": 1,
            "type": "header",
            "bbox": {
                "l": 78.96,
                "t": 749.04,
                "r": 289.2,
                "b": 716.16
            },
            "text": "SRQ GENERAL AVIATION FIS FACILITY\nSARASOTA MANATEE AIRPORT AUTHORITY",
            "attrs": {
                "block_label": "header"
            },
            "level": 2
        },
        {
            "id": "p38.2",
            "order": 2,
            "type": "figure",
            "bbox": {
                "l": 467.52,
                "t": 756.72,
                "r": 533.28,
                "b": 718.32
            },
            "text": "",
            "attrs": {
                "role": "page_header",
                "block_label": "header_image",
                "embedded_text": "C®S\nCOMPANIES\""
            }
        },
        {
            "id": "p38.3",
            "order": 3,
            "type": "list",
            "bbox": {
                "l": 130.08,
                "t": 701.28,
                "r": 535.2,
                "b": 435.84
            },
            "text": "",
            "attrs": {
                "item_count": 8
            },
            "children": [
                {
                    "id": "p38.3.1",
                    "order": 4,
                    "type": "list_item",
                    "bbox": {
                        "l": 130.08,
                        "t": 701.28,
                        "r": 351.6,
                        "b": 686.64
                    },
                    "text": "Establish utility service and distribution",
                    "marker": "2."
                },
                {
                    "id": "p38.3.2",
                    "order": 5,
                    "type": "list_item",
                    "bbox": {
                        "l": 130.32,
                        "t": 674.64,
                        "r": 534.72,
                        "b": 643.44
                    },
                    "text": "A one-line diagram will be developed with appropriate panel board sizes and feeder sizes with taking into account any voltage drop",
                    "marker": "3."
                },
                {
                    "id": "p38.3.3",
                    "order": 6,
                    "type": "list_item",
                    "bbox": {
                        "l": 130.8,
                        "t": 631.92,
                        "r": 534.48,
                        "b": 601.68
                    },
                    "text": "Stand-by generator and automatic transfer switch will be selected and designed",
                    "marker": "4."
                },
                {
                    "id": "p38.3.4",
                    "order": 7,
                    "type": "list_item",
                    "bbox": {
                        "l": 131.04,
                        "t": 589.92,
                        "r": 508.32,
                        "b": 574.32
                    },
                    "text": "Branch circuits (equipment, receptacles, and lighting) will be designed",
                    "marker": "5."
                },
                {
                    "id": "p38.3.5",
                    "order": 8,
                    "type": "list_item",
                    "bbox": {
                        "l": 131.04,
                        "t": 563.04,
                        "r": 310.8,
                        "b": 548.4
                    },
                    "text": "Panel schedules will be created",
                    "marker": "6."
                },
                {
                    "id": "p38.3.6",
                    "order": 9,
                    "type": "list_item",
                    "bbox": {
                        "l": 131.04,
                        "t": 536.16,
                        "r": 534.48,
                        "b": 504.96
                    },
                    "text": "Power distribution will be provided for all mechanical equipment for heating, cooling and ventilation, and for all communications and security",
                    "marker": "7."
                },
                {
                    "id": "p38.3.7",
                    "order": 10,
                    "type": "list_item",
                    "bbox": {
                        "l": 131.04,
                        "t": 493.92,
                        "r": 535.2,
                        "b": 463.2
                    },
                    "text": "Receptacles and floor boxes will be placed within the floor plan with input from CBP personnel",
                    "marker": "8."
                },
                {
                    "id": "p38.3.8",
                    "order": 11,
                    "type": "list_item",
                    "bbox": {
                        "l": 130.56,
                        "t": 451.68,
                        "r": 454.08,
                        "b": 435.84
                    },
                    "text": "Further Develop parking lot lighting plan and photometrics",
                    "marker": "9."
                }
            ]
        },
        {
            "id": "p38.4",
            "order": 12,
            "type": "heading",
            "bbox": {
                "l": 131.04,
                "t": 424.56,
                "r": 285.6,
                "b": 409.92
            },
            "text": "Communications and Security",
            "attrs": {
                "block_label": "paragraph_title"
            },
            "level": 3
        },
        {
            "id": "p38.5",
            "order": 13,
            "type": "list",
            "bbox": {
                "l": 130.08,
                "t": 397.92,
                "r": 534.48,
                "b": 201.6
            },
            "text": "",
            "attrs": {
                "item_count": 6
            },
            "children": [
                {
                    "id": "p38.5.1",
                    "order": 14,
                    "type": "list_item",
                    "bbox": {
                        "l": 131.28,
                        "t": 397.92,
                        "r": 534,
                        "b": 366.72
                    },
                    "text": "Further Develop security system based on previous coordination with CBP and any comments from previous submission",
                    "marker": "1."
                },
                {
                    "id": "p38.5.2",
                    "order": 15,
                    "type": "list_item",
                    "bbox": {
                        "l": 130.08,
                        "t": 355.44,
                        "r": 534.48,
                        "b": 324.96
                    },
                    "text": "Further Develop communication system based on previous coordination with CBP and any comments from previous submission",
                    "marker": "2."
                },
                {
                    "id": "p38.5.3",
                    "order": 16,
                    "type": "list_item",
                    "bbox": {
                        "l": 130.32,
                        "t": 312.96,
                        "r": 516.72,
                        "b": 298.08
                    },
                    "text": "Coordinate with mechanical for cooling requirements for telecom room",
                    "marker": "3."
                },
                {
                    "id": "p38.5.4",
                    "order": 17,
                    "type": "list_item",
                    "bbox": {
                        "l": 130.08,
                        "t": 286.56,
                        "r": 399.36,
                        "b": 270.72
                    },
                    "text": "Develop routing of main above ceiling pathways",
                    "marker": "4."
                },
                {
                    "id": "p38.5.5",
                    "order": 18,
                    "type": "list_item",
                    "bbox": {
                        "l": 130.32,
                        "t": 259.2,
                        "r": 534,
                        "b": 228.96
                    },
                    "text": "Coordinate with CBP and SRQ security and IT departments for connection routing and requirements",
                    "marker": "5."
                },
                {
                    "id": "p38.5.6",
                    "order": 19,
                    "type": "list_item",
                    "bbox": {
                        "l": 130.32,
                        "t": 216.96,
                        "r": 417.84,
                        "b": 201.6
                    },
                    "text": "Finalize sizes of major communications components",
                    "marker": "6."
                }
            ]
        },
        {
            "id": "p38.6",
            "order": 20,
            "type": "heading",
            "bbox": {
                "l": 95.76,
                "t": 184.32,
                "r": 140.64,
                "b": 170.4
            },
            "text": "TasK 26",
            "attrs": {
                "block_label": "paragraph_title"
            },
            "level": 3
        },
        {
            "id": "p38.7",
            "order": 21,
            "type": "text",
            "bbox": {
                "l": 95.52,
                "t": 163.2,
                "r": 534,
                "b": 132.48
            },
            "text": "Develop preliminary front end specifications by reviewing SRQ provided Division 0 and Division 1 documents."
        },
        {
            "id": "p38.8",
            "order": 22,
            "type": "heading",
            "bbox": {
                "l": 113.28,
                "t": 120.48,
                "r": 178.08,
                "b": 107.52
            },
            "text": "DELIVERABLE",
            "attrs": {
                "block_label": "paragraph_title"
            },
            "level": 3
        },
        {
            "id": "p38.9",
            "order": 23,
            "type": "list_item",
            "bbox": {
                "l": 113.04,
                "t": 105.36,
                "r": 370.8,
                "b": 90.96
            },
            "text": "Preliminary Front End Specifications for review",
            "marker": "-"
        },
        {
            "id": "p38.10",
            "order": 24,
            "type": "footer",
            "bbox": {
                "l": 480,
                "t": 66,
                "r": 533.28,
                "b": 54
            },
            "text": "Page 26 of 93",
            "attrs": {
                "block_label": "number"
            }
        },
        {
            "id": "p38.11",
            "order": 25,
            "type": "footer",
            "bbox": {
                "l": 79.2,
                "t": 67.2,
                "r": 138.24,
                "b": 54.48
            },
            "text": "August 2, 2021",
            "attrs": {
                "block_label": "footer"
            }
        }
    ],
    "excluded_furniture": {
        "first": [],
        "last": []
    }
}