    "document_id": 10400,
    "page": 37,
    "width_pt": 612,
    "height_pt": 792,
    "rotation": 0,
    "pipeline_version": "paddleocr-vl-1.6+paul-48",
    "engine": "paddleocr_vl",
    "source_run_id": 10511,
    "item_count": 29,
    "counts_by_type": {
        "figure": 1,
        "footer": 2,
        "header": 1,
        "heading": 3,
        "list": 3,
        "list_item": 18,
        "text": 1
    },
    "build_ms": 2,
    "items": [
        {
            "id": "p37.1",
            "order": 1,
            "type": "header",
            "bbox": {
                "l": 75.84,
                "t": 751.2,
                "r": 286.32,
                "b": 718.8
            },
            "text": "SRQ GENERAL AVIATION FIS FACILITY\nSARASOTA MANATEE AIRPORT AUTHORITY",
            "attrs": {
                "block_label": "header"
            },
            "level": 2
        },
        {
            "id": "p37.2",
            "order": 2,
            "type": "figure",
            "bbox": {
                "l": 464.88,
                "t": 759.36,
                "r": 531.36,
                "b": 722.16
            },
            "text": "",
            "attrs": {
                "role": "page_header",
                "block_label": "header_image",
                "embedded_text": "Cf&S\nCOMPANIES\""
            }
        },
        {
            "id": "p37.3",
            "order": 3,
            "type": "list",
            "bbox": {
                "l": 127.68,
                "t": 703.68,
                "r": 533.04,
                "b": 618.96
            },
            "text": "",
            "attrs": {
                "item_count": 3
            },
            "children": [
                {
                    "id": "p37.3.1",
                    "order": 4,
                    "type": "list_item",
                    "bbox": {
                        "l": 127.68,
                        "t": 703.68,
                        "r": 533.04,
                        "b": 673.44
                    },
                    "text": "Develop routing of piping mains based on previous calculations and coordinate with foundation plans",
                    "marker": "5."
                },
                {
                    "id": "p37.3.2",
                    "order": 5,
                    "type": "list_item",
                    "bbox": {
                        "l": 127.92,
                        "t": 661.2,
                        "r": 421.2,
                        "b": 646.56
                    },
                    "text": "Coordinate layout of plumbing fixtures with architect",
                    "marker": "6."
                },
                {
                    "id": "p37.3.3",
                    "order": 6,
                    "type": "list_item",
                    "bbox": {
                        "l": 127.92,
                        "t": 634.56,
                        "r": 530.4,
                        "b": 618.96
                    },
                    "text": "Develop technical specifications in accordance with building programming",
                    "marker": "7."
                }
            ]
        },
        {
            "id": "p37.4",
            "order": 7,
            "type": "heading",
            "bbox": {
                "l": 129.12,
                "t": 606.96,
                "r": 190.8,
                "b": 593.04
            },
            "text": "Mechanical",
            "attrs": {
                "block_label": "paragraph_title"
            },
            "level": 3
        },
        {
            "id": "p37.5",
            "order": 8,
            "type": "list",
            "bbox": {
                "l": 127.68,
                "t": 580.08,
                "r": 533.52,
                "b": 333.36
            },
            "text": "",
            "attrs": {
                "item_count": 9
            },
            "children": [
                {
                    "id": "p37.5.1",
                    "order": 9,
                    "type": "list_item",
                    "bbox": {
                        "l": 128.64,
                        "t": 580.08,
                        "r": 464.4,
                        "b": 565.68
                    },
                    "text": "Finalize sizes for HVAC equipment based on load calculations",
                    "marker": "1."
                },
                {
                    "id": "p37.5.2",
                    "order": 10,
                    "type": "list_item",
                    "bbox": {
                        "l": 127.68,
                        "t": 553.2,
                        "r": 524.4,
                        "b": 538.32
                    },
                    "text": "Coordinate with vendors and finalize unit selections for HVAC equipment",
                    "marker": "2."
                },
                {
                    "id": "p37.5.3",
                    "order": 11,
                    "type": "list_item",
                    "bbox": {
                        "l": 128.4,
                        "t": 526.32,
                        "r": 533.52,
                        "b": 495.36
                    },
                    "text": "Ductwork and mechanical pipe routing will be further developed to provide necessary cooling/heating",
                    "marker": "3."
                },
                {
                    "id": "p37.5.4",
                    "order": 12,
                    "type": "list_item",
                    "bbox": {
                        "l": 127.92,
                        "t": 483.6,
                        "r": 464.64,
                        "b": 468.96
                    },
                    "text": "Coordinate with Architectural for ceiling and floor plan layout",
                    "marker": "4."
                },
                {
                    "id": "p37.5.5",
                    "order": 13,
                    "type": "list_item",
                    "bbox": {
                        "l": 128.16,
                        "t": 456.72,
                        "r": 533.28,
                        "b": 442.08
                    },
                    "text": "Diffuser and return locations will be indicated with preliminary airflow rates",
                    "marker": "5."
                },
                {
                    "id": "p37.5.6",
                    "order": 14,
                    "type": "list_item",
                    "bbox": {
                        "l": 128.4,
                        "t": 430.08,
                        "r": 308.88,
                        "b": 414.72
                    },
                    "text": "Develop project specific details",
                    "marker": "6."
                },
                {
                    "id": "p37.5.7",
                    "order": 15,
                    "type": "list_item",
                    "bbox": {
                        "l": 128.64,
                        "t": 402.72,
                        "r": 511.2,
                        "b": 388.08
                    },
                    "text": "Provide updated mechanical schedules based on equipment selections",
                    "marker": "7."
                },
                {
                    "id": "p37.5.8",
                    "order": 16,
                    "type": "list_item",
                    "bbox": {
                        "l": 128.4,
                        "t": 375.6,
                        "r": 497.52,
                        "b": 360.96
                    },
                    "text": "Finalize electrical loads for equipment and coordinate with Electrical",
                    "marker": "8."
                },
                {
                    "id": "p37.5.9",
                    "order": 17,
                    "type": "list_item",
                    "bbox": {
                        "l": 128.4,
                        "t": 348.72,
                        "r": 356.64,
                        "b": 333.36
                    },
                    "text": "Develop preliminary energy calculations.",
                    "marker": "9."
                }
            ]
        },
        {
            "id": "p37.6",
            "order": 18,
            "type": "heading",
            "bbox": {
                "l": 129.12,
                "t": 321.12,
                "r": 205.44,
                "b": 307.44
            },
            "text": "Fire Protection",
            "attrs": {
                "block_label": "paragraph_title"
            },
            "level": 3
        },
        {
            "id": "p37.7",
            "order": 19,
            "type": "list",
            "bbox": {
                "l": 128.16,
                "t": 294.72,
                "r": 459.12,
                "b": 144.72
            },
            "text": "",
            "attrs": {
                "item_count": 6
            },
            "children": [
                {
                    "id": "p37.7.1",
                    "order": 20,
                    "type": "list_item",
                    "bbox": {
                        "l": 128.88,
                        "t": 294.72,
                        "r": 372.24,
                        "b": 279.36
                    },
                    "text": "Develop sprinkler coverage area and layout",
                    "marker": "1."
                },
                {
                    "id": "p37.7.2",
                    "order": 21,
                    "type": "list_item",
                    "bbox": {
                        "l": 128.4,
                        "t": 267.36,
                        "r": 305.76,
                        "b": 252.24
                    },
                    "text": "Develop sprinkler pipe routing",
                    "marker": "2."
                },
                {
                    "id": "p37.7.3",
                    "order": 22,
                    "type": "list_item",
                    "bbox": {
                        "l": 128.4,
                        "t": 240.72,
                        "r": 399.36,
                        "b": 225.84
                    },
                    "text": "Develop fire alarm and notification device layout",
                    "marker": "3."
                },
                {
                    "id": "p37.7.4",
                    "order": 23,
                    "type": "list_item",
                    "bbox": {
                        "l": 128.4,
                        "t": 213.84,
                        "r": 402.96,
                        "b": 198.96
                    },
                    "text": "Develop fire alarm sequence of operations matrix",
                    "marker": "4."
                },
                {
                    "id": "p37.7.5",
                    "order": 24,
                    "type": "list_item",
                    "bbox": {
                        "l": 128.64,
                        "t": 186.24,
                        "r": 432.96,
                        "b": 171.6
                    },
                    "text": "Develop fire protection systems technical specifications",
                    "marker": "5."
                },
                {
                    "id": "p37.7.6",
                    "order": 25,
                    "type": "list_item",
                    "bbox": {
                        "l": 128.16,
                        "t": 159.6,
                        "r": 459.12,
                        "b": 144.72
                    },
                    "text": "Coordinate interfaces with mechanical and electrical systems",
                    "marker": "6."
                }
            ]
        },
        {
            "id": "p37.8",
            "order": 26,
            "type": "heading",
            "bbox": {
                "l": 129.84,
                "t": 132.24,
                "r": 178.56,
                "b": 118.56
            },
            "text": "Electrical",
            "attrs": {
                "block_label": "paragraph_title"
            },
            "level": 3
        },
        {
            "id": "p37.9",
            "order": 27,
            "type": "text",
            "bbox": {
                "l": 129.36,
                "t": 105.36,
                "r": 333.12,
                "b": 90.96
            },
            "text": "1. Finalize electrical load requirements"
        },
        {
            "id": "p37.10",
            "order": 28,
            "type": "footer",
            "bbox": {
                "l": 478.8,
                "t": 66.72,
                "r": 533.04,
                "b": 54.72
            },
            "text": "Page 25 of 93",
            "attrs": {
                "block_label": "number"
            }
        },
        {
            "id": "p37.11",
            "order": 29,
            "type": "footer",
            "bbox": {
                "l": 77.04,
                "t": 66.72,
                "r": 136.08,
                "b": 54
            },
            "text": "August 2, 2021",
            "attrs": {
                "block_label": "footer"
            }
        }
    ],
    "excluded_furniture": {
        "first": [],
        "last": []
    }
}