{
    "document_id": 10376,
    "page": 118,
    "width_pt": 612,
    "height_pt": 792,
    "rotation": 0,
    "pipeline_version": "paddleocr-vl-1.6+paul-48",
    "engine": "paddleocr_vl",
    "source_run_id": 10488,
    "item_count": 39,
    "counts_by_type": {
        "figure": 2,
        "footer": 2,
        "header": 2,
        "heading": 4,
        "list": 4,
        "list_item": 24,
        "text": 1
    },
    "build_ms": 4,
    "items": [
        {
            "id": "p118.1",
            "order": 1,
            "type": "header",
            "bbox": {
                "l": 140.64,
                "t": 774.24,
                "r": 469.92,
                "b": 762.48
            },
            "text": "November 22, 2021 Board Meeting - Items Needing Action - Over $325,000 Threshold",
            "attrs": {
                "block_label": "header"
            },
            "level": 2
        },
        {
            "id": "p118.2",
            "order": 2,
            "type": "figure",
            "bbox": {
                "l": 77.52,
                "t": 709.68,
                "r": 107.28,
                "b": 680.16
            },
            "text": "",
            "attrs": {
                "role": "page_header",
                "block_label": "header_image"
            }
        },
        {
            "id": "p118.3",
            "order": 3,
            "type": "header",
            "bbox": {
                "l": 459.6,
                "t": 693.12,
                "r": 527.76,
                "b": 672.72
            },
            "text": "Scope of Services\nNovember 9, 2021",
            "attrs": {
                "block_label": "header"
            },
            "level": 2
        },
        {
            "id": "p118.4",
            "order": 4,
            "type": "figure",
            "bbox": {
                "l": 22.2302,
                "t": 764.3055,
                "r": 591.6307,
                "b": 27.4343
            },
            "text": "",
            "attrs": {
                "source": "pdf_image"
            }
        },
        {
            "id": "p118.5",
            "order": 5,
            "type": "heading",
            "bbox": {
                "l": 272.64,
                "t": 694.56,
                "r": 331.92,
                "b": 683.76
            },
            "text": "SCOPE DETAIL",
            "attrs": {
                "block_label": "paragraph_title"
            },
            "level": 3
        },
        {
            "id": "p118.6",
            "order": 6,
            "type": "list",
            "bbox": {
                "l": 158.4,
                "t": 653.76,
                "r": 516,
                "b": 558.48
            },
            "text": "",
            "attrs": {
                "item_count": 5
            },
            "children": [
                {
                    "id": "p118.6.1",
                    "order": 7,
                    "type": "list_item",
                    "bbox": {
                        "l": 160.32,
                        "t": 653.76,
                        "r": 516,
                        "b": 618.96
                    },
                    "text": "Show telecommunication space equipment and furniture layout. Identify key components including monitoring sensors, raised floor and cable tray systems, and interdisciplinary device coordination.",
                    "marker": "ii."
                },
                {
                    "id": "p118.6.2",
                    "order": 8,
                    "type": "list_item",
                    "bbox": {
                        "l": 158.64,
                        "t": 617.76,
                        "r": 466.08,
                        "b": 594.24
                    },
                    "text": "Provide network cabinet and wall elevations detailing equipment positions and interconnections (Task 2 only)",
                    "marker": "iii."
                },
                {
                    "id": "p118.6.3",
                    "order": 9,
                    "type": "list_item",
                    "bbox": {
                        "l": 158.4,
                        "t": 593.28,
                        "r": 492,
                        "b": 582.48
                    },
                    "text": "Provide single line and system diagrams, for all intended telecommunications systems.",
                    "marker": "iv."
                },
                {
                    "id": "p118.6.4",
                    "order": 10,
                    "type": "list_item",
                    "bbox": {
                        "l": 159.36,
                        "t": 580.8,
                        "r": 505.92,
                        "b": 570
                    },
                    "text": "Provide equipment and installation details, riser diagrams, schedules and set coordination.",
                    "marker": "v."
                },
                {
                    "id": "p118.6.5",
                    "order": 11,
                    "type": "list_item",
                    "bbox": {
                        "l": 159.84,
                        "t": 569.52,
                        "r": 326.16,
                        "b": 558.48
                    },
                    "text": "Provide outline division 27 specifications",
                    "marker": "vi."
                }
            ]
        },
        {
            "id": "p118.7",
            "order": 12,
            "type": "heading",
            "bbox": {
                "l": 143.28,
                "t": 557.04,
                "r": 194.4,
                "b": 546.48
            },
            "text": "b. Security:",
            "attrs": {
                "block_label": "paragraph_title"
            },
            "level": 3
        },
        {
            "id": "p118.8",
            "order": 13,
            "type": "list",
            "bbox": {
                "l": 158.4,
                "t": 545.28,
                "r": 514.56,
                "b": 401.76
            },
            "text": "",
            "attrs": {
                "item_count": 6
            },
            "children": [
                {
                    "id": "p118.8.1",
                    "order": 14,
                    "type": "list_item",
                    "bbox": {
                        "l": 160.8,
                        "t": 545.28,
                        "r": 502.56,
                        "b": 522.24
                    },
                    "text": "Layout communication and power pathways and routing plan for security devices provide pathway types and sizes, cable quantities and characteristics.",
                    "marker": "i."
                },
                {
                    "id": "p118.8.2",
                    "order": 15,
                    "type": "list_item",
                    "bbox": {
                        "l": 159.84,
                        "t": 521.28,
                        "r": 501.12,
                        "b": 509.76
                    },
                    "text": "Show camera locations, view angles, and installation details for CCTV based on SD report.",
                    "marker": "ii."
                },
                {
                    "id": "p118.8.3",
                    "order": 16,
                    "type": "list_item",
                    "bbox": {
                        "l": 158.64,
                        "t": 508.8,
                        "r": 514.56,
                        "b": 486.48
                    },
                    "text": "Show door locations, specific electronic access control devices, and movement sensor device locations based on SD report.",
                    "marker": "iii."
                },
                {
                    "id": "p118.8.4",
                    "order": 17,
                    "type": "list_item",
                    "bbox": {
                        "l": 158.4,
                        "t": 485.28,
                        "r": 508.32,
                        "b": 450
                    },
                    "text": "Provide sequence of operations for ACS including integration with CCTV and/or existing systems. Include detailed information on normally open or closed characteristics and other parameters.",
                    "marker": "iv."
                },
                {
                    "id": "p118.8.5",
                    "order": 18,
                    "type": "list_item",
                    "bbox": {
                        "l": 159.6,
                        "t": 449.04,
                        "r": 498.96,
                        "b": 413.76
                    },
                    "text": "Detail security riser diagrams, security rack layouts, and wall elevations. Provide detailed schedules for CCTV and ACS doors outlining all essential installation and configuration parameters.",
                    "marker": "v."
                },
                {
                    "id": "p118.8.6",
                    "order": 19,
                    "type": "list_item",
                    "bbox": {
                        "l": 158.88,
                        "t": 413.04,
                        "r": 325.92,
                        "b": 401.76
                    },
                    "text": "Provide outline division 28 specifications",
                    "marker": "vi."
                }
            ]
        },
        {
            "id": "p118.9",
            "order": 20,
            "type": "heading",
            "bbox": {
                "l": 142.56,
                "t": 388.8,
                "r": 241.92,
                "b": 378.48
            },
            "text": "c. Audio Visual Systems:",
            "attrs": {
                "block_label": "paragraph_title"
            },
            "level": 3
        },
        {
            "id": "p118.10",
            "order": 21,
            "type": "list",
            "bbox": {
                "l": 158.4,
                "t": 377.04,
                "r": 507.36,
                "b": 258
            },
            "text": "",
            "attrs": {
                "item_count": 5
            },
            "children": [
                {
                    "id": "p118.10.1",
                    "order": 22,
                    "type": "list_item",
                    "bbox": {
                        "l": 161.28,
                        "t": 377.04,
                        "r": 503.76,
                        "b": 341.76
                    },
                    "text": "Speaker, microphone, digital display, amplification, control and distribution equipment\nlayout for conference rooms, auditoriums, lobbies, etc. based on calculations and findings from SD phase.",
                    "marker": "i."
                },
                {
                    "id": "p118.10.2",
                    "order": 23,
                    "type": "list_item",
                    "bbox": {
                        "l": 160.32,
                        "t": 341.04,
                        "r": 460.56,
                        "b": 318
                    },
                    "text": "A/V block diagrams for audio, video and control distribution, including system interconnection and integration.",
                    "marker": "ii."
                },
                {
                    "id": "p118.10.3",
                    "order": 24,
                    "type": "list_item",
                    "bbox": {
                        "l": 158.4,
                        "t": 316.8,
                        "r": 507.36,
                        "b": 294
                    },
                    "text": "Installation details for displays, speakers, etc. including coordination with architectural and structural enclosures.",
                    "marker": "ii."
                },
                {
                    "id": "p118.10.4",
                    "order": 25,
                    "type": "list_item",
                    "bbox": {
                        "l": 158.88,
                        "t": 292.56,
                        "r": 319.2,
                        "b": 281.52
                    },
                    "text": "Equipment rack layouts and elevations",
                    "marker": "iv."
                },
                {
                    "id": "p118.10.5",
                    "order": 26,
                    "type": "list_item",
                    "bbox": {
                        "l": 160.08,
                        "t": 280.8,
                        "r": 489.84,
                        "b": 258
                    },
                    "text": "Specifications defining hardware and software parameters, control requirements, and installation details and configurations.",
                    "marker": "v."
                }
            ]
        },
        {
            "id": "p118.11",
            "order": 27,
            "type": "heading",
            "bbox": {
                "l": 143.52,
                "t": 256.32,
                "r": 198.48,
                "b": 245.76
            },
            "text": "d. Software:",
            "level": 3
        },
        {
            "id": "p118.12",
            "order": 28,
            "type": "list",
            "bbox": {
                "l": 111.12,
                "t": 244.8,
                "r": 510.48,
                "b": 137.28
            },
            "text": "",
            "attrs": {
                "item_count": 8
            },
            "children": [
                {
                    "id": "p118.12.1",
                    "order": 29,
                    "type": "list_item",
                    "bbox": {
                        "l": 111.12,
                        "t": 244.8,
                        "r": 510.48,
                        "b": 221.76
                    },
                    "text": "Software requirements must be defined in specifications including all workstations required. Task 2 Design Development Deliverables include:",
                    "marker": "i."
                },
                {
                    "id": "p118.12.2",
                    "order": 30,
                    "type": "list_item",
                    "bbox": {
                        "l": 127.44,
                        "t": 220.08,
                        "r": 300.96,
                        "b": 209.04
                    },
                    "text": "New and removal work drawings including",
                    "marker": "a."
                },
                {
                    "id": "p118.12.3",
                    "order": 31,
                    "type": "list_item",
                    "bbox": {
                        "l": 154.08,
                        "t": 208.56,
                        "r": 262.32,
                        "b": 197.76
                    },
                    "text": "Devices to be removed",
                    "marker": "i."
                },
                {
                    "id": "p118.12.4",
                    "order": 32,
                    "type": "list_item",
                    "bbox": {
                        "l": 152.64,
                        "t": 196.08,
                        "r": 251.28,
                        "b": 185.28
                    },
                    "text": "Backbone pathways",
                    "marker": "ii."
                },
                {
                    "id": "p118.12.5",
                    "order": 33,
                    "type": "list_item",
                    "bbox": {
                        "l": 151.44,
                        "t": 183.84,
                        "r": 315.36,
                        "b": 173.28
                    },
                    "text": "Proposed device locations all systems",
                    "marker": "iii."
                },
                {
                    "id": "p118.12.6",
                    "order": 34,
                    "type": "list_item",
                    "bbox": {
                        "l": 126.72,
                        "t": 172.8,
                        "r": 374.4,
                        "b": 161.52
                    },
                    "text": "Telecommunications rooms preliminary layouts and elevations",
                    "marker": "b."
                },
                {
                    "id": "p118.12.7",
                    "order": 35,
                    "type": "list_item",
                    "bbox": {
                        "l": 127.2,
                        "t": 160.08,
                        "r": 289.92,
                        "b": 149.52
                    },
                    "text": "Preliminary rack and cabinet elevations",
                    "marker": "c."
                },
                {
                    "id": "p118.12.8",
                    "order": 36,
                    "type": "list_item",
                    "bbox": {
                        "l": 127.44,
                        "t": 148.32,
                        "r": 212.64,
                        "b": 137.28
                    },
                    "text": "Systems diagrams",
                    "marker": "d."
                }
            ]
        },
        {
            "id": "p118.13",
            "order": 37,
            "type": "text",
            "bbox": {
                "l": 489.6,
                "t": 86.64,
                "r": 523.2,
                "b": 76.8
            },
            "text": "Page | 41",
            "attrs": {
                "block_label": "number"
            }
        },
        {
            "id": "p118.14",
            "order": 38,
            "type": "footer",
            "bbox": {
                "l": 79.2,
                "t": 114.96,
                "r": 142.56,
                "b": 84.48
            },
            "text": "",
            "attrs": {
                "block_label": "footer_image"
            }
        },
        {
            "id": "p118.15",
            "order": 39,
            "type": "footer",
            "bbox": {
                "l": 298.56,
                "t": 25.68,
                "r": 314.16,
                "b": 15.84
            },
            "text": "118",
            "attrs": {
                "block_label": "number"
            }
        }
    ],
    "excluded_furniture": {
        "first": [],
        "last": []
    }
}